Setup
Vacuum De-gas
This procedure is for assemblies with Vacuum Tree Manifold and No Agitator or
10341015
ti12560a
FIG. 7
1.Models with ADM: To prevent machine movement,
press the Machine Disable Mode key (). Models with SDM: To prevent machine movement, press the Red button
.
2.Close the
3.If the tank lid has a fill port, turn off any systems that might refill the tank during the vacuum
4.Close the fill port ball valve (1034).
5.If the tank lid requires a desiccant dryer or nitrogen pump installed, install one into the top ball valve of the vacuum tree manifold (1015).
6.Close the top ball valve of the vacuum tree manifold (1015).
7.Attach vacuum pump to the bottom ball valve of the vacuum tree manifold (1015) then open the ball valve.
8.Turn on the vacuum pump.
9.Continue to
10.Close bottom ball valve of the vacuum tree manifold (1015).
11.Turn off the vacuum pump.
12.Open the top ball valve of the vacuum tree manifold (1015).
CAUTION
Operating the tank after the vacuum
13. Open the shutoff valves at the base of the tanks.
20 | 312394V |