SECTION 6 − OPERATION
6-1. Controls
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | |||||||||||
1 Wire Speed Control
Use control to select a wire feed speed. As Voltage switch setting increases, wire speed range also increases (see weld setting label in welding power source or Sections
2 Power Switch
3 | 4 | |
2 | DO NOT SWITCH | |
WHILE WELDING | ||
| ||
| NE PAS CHANGER | |
| DE PROCÉDÉ |
1P U R G E
V
34
Ref. 217
3 Voltage Switch | 4 Voltage Switch - “Purge” Position |
The higher the selected number, the | In purge position, fan runs but there is no |
thicker the material that can be welded | weld output or wire feed. Use “PURGE” |
(see weld setting label in welding power | setting when adjusting gas flow at the |
source or Sections | regulator. |
applicable). Do not switch under load. |
|
.Switch must “click” into detent position 1, 2, 3, 4, or purge for proper contact.