Carrier installation manual 38VYX110/38VYX130 Heat pump split system outdoor units, Contents

Page 2

38VYX110/38VYX130

 

Heat pump split system outdoor units

 

For operation and maintenance instructions of this unit as well as installation

 

instructions of the indoor unit, refer to the relevant manuals.

 

Contents

 

 

Page

Precautions for safety

2

Accessory and refrigerant

3

Selection of installation

3/4

Refrigerant piping

5

Evacuating

9/10

Electrical connections

10

Final installation checks

11/12

ATTENTION INSTALLERS AND SERVICE TECHNICIANS!

AIR CONDITIONER WITH R-410A – QUICK REFERENCE GUIDE

R-410A refrigerant operates at 50%-70% higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with R-410A.

R-410A refrigerant cylinders are pink.

R-410A refrigerant cylinders have a dip tube which allows liquid to flow out with the cylinder in a vertical position with the valve at the top.

R-410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose in order to vaporize the liquid refrigerant before it enters in the unit.

A vacuum pump is not enough to remove moisture from oil.

Oils absorb moisture rapidly. Do not expose oil to atmosphere.

Never open system to atmosphere while it is under vacuum.

When the system must be opened for service, break vacuum with dry nitrogen.

Do not vent R-410A into the atmosphere.

Use only Carrier matching indoor units (Table I).

Table I

Heat

Cassette

Satellite

Power

 

pump

 

“40KQV”

“40SQV”

supply

 

models

 

 

 

 

 

 

 

 

 

 

38VYX 110

110

110

 

 

38VYX 130

130

130

220240V ~ 50Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

GB - 1

Image 2 Contents
38VYX110/38VYX130 Contents 38VYX110/38VYX130 Heat pump split system outdoor unitsGeneral information Precautions for safetyRequired tools for installation work R410A Special requirementAccessory and refrigerant Selection of installationHow to remove the front panel Installation PlaceCover knockout for pipe connection Knockout procedure Table V Pipe outer diameter Refrigerant pipingFlaring Outer dia. of copper pipe R410A R22Upper side is free Minimum clearancesObstacle at rear side Obstacle also at the upper sideObstacles at both front and rear sides InstallationStandard installation 38 VYXTable Viii Air Purge Table VI Optional Installation PartsTable VII Piping connection 38VYX110 38VYX130 EvacuatingVacuum pump Close OpenElectrical connections Valve handling precautionsPower cable and connecting cable Make refrigerant connections before electrical connectionsUseful Functions Final installation checksCheck and Test Operation LED indication and code checkingChanges in the product and components Installation/Servicing ToolsTable New tools for R410A New tools for R410A Applicable to R22 model Changes38VYX Via R. Sanzio, 9 20058 Villasanta MI Italy Tel /3636.1