Minimum clearances

E N G L I S H

Obstacles at both front and rear sides

Standard installation

Open the upper side and both right and left sides.

The height of obstacle at both front and rear side, should be lower than the height of the outdoor unit.

Single unit installation

150

more

 

 

 

 

or

 

 

 

 

ormore

 

 

 

 

 

 

 

1000

 

 

 

 

 

Serial installation of two or more units

 

 

200

more

 

 

 

or

300

300

1000

moreor

 

 

or more

or more

 

 

Serial installation at front and rear sides

Standard installation

Open the upper side and both right and left sides.

The height of obstacle at both front and rear side, should be lower than the height of the outdoor unit.

1000

300

1500

2000

200

or more

or more

or more

or more

or more

Installation

38 VYX 110-130

150600

Drain hole

150

430

400

365

Knockout

Drain nipple

hole

mounting hole

15 mm or less

• Set the out margin of the anchor bolt to 15mm or less..

 

Before installation, check strength and horizontality of the base so that abnormal sound does not generate.

According to the following base diagram, fix the base firmly with the anchor bolts.

(Anchor bolt, nut: M10 x 2 pairs)

GB - 7

Image 8
Contents 38VYX110/38VYX130 Contents 38VYX110/38VYX130 Heat pump split system outdoor unitsPrecautions for safety Required tools for installation workGeneral information R410A Special requirementAccessory and refrigerant Selection of installationHow to remove the front panel Installation PlaceCover knockout for pipe connection Knockout procedure Refrigerant piping FlaringTable V Pipe outer diameter Outer dia. of copper pipe R410A R22Minimum clearances Obstacle at rear sideUpper side is free Obstacle also at the upper sideInstallation Standard installationObstacles at both front and rear sides 38 VYXTable Viii Air Purge Table VI Optional Installation PartsTable VII Piping connection Evacuating Vacuum pump38VYX110 38VYX130 Close OpenValve handling precautions Power cable and connecting cableElectrical connections Make refrigerant connections before electrical connectionsFinal installation checks Check and Test OperationUseful Functions LED indication and code checkingInstallation/Servicing Tools Table New tools for R410AChanges in the product and components New tools for R410A Applicable to R22 model Changes38VYX Via R. Sanzio, 9 20058 Villasanta MI Italy Tel /3636.1

38VYX110, 38VYX130 specifications

The Carrier 38VYX130 and 38VYX110 are advanced air conditioning units designed for residential and light commercial applications, offering optimal energy efficiency, reliable performance, and enhanced comfort. These models exemplify Carrier's commitment to delivering high-quality climate control solutions.

One of the standout features of the Carrier 38VYX series is its energy efficiency. Both the 38VYX130 and 38VYX110 boast a high Seasonal Energy Efficiency Ratio (SEER) rating, indicating their ability to provide effective cooling while consuming less energy. This makes them an environmentally friendly option, as well as a cost-effective choice for homeowners and businesses looking to reduce their energy bills.

The 38VYX130 and 38VYX110 utilize inverter technology, which allows the compressor to adjust its speed based on the cooling demand. This not only enhances energy efficiency but also ensures consistent comfort levels by minimizing temperature fluctuations. This feature is particularly beneficial in variable weather conditions, providing a stable indoor climate without excessive energy consumption.

Another significant technological advancement in these models is the use of R-410A refrigerant, which is known for its low environmental impact compared to traditional refrigerants. This aligns with Carrier's commitment to sustainability and reducing the carbon footprint of their products. Additionally, both units are equipped with advanced filtration systems that help improve indoor air quality by capturing dust, allergens, and other airborne particles.

The Carrier 38VYX series is also designed with quiet operation in mind. With sound levels that fall within the low dB range, these units ensure that homeowners can enjoy a comfortable living environment without disruptive noise, whether the system is running during the day or at night.

For ease of installation and maintenance, the 38VYX130 and 38VYX110 come with user-friendly features, including a compact design that allows for flexible placement and service access. Furthermore, Carrier offers a robust warranty and customer support, ensuring peace of mind for users.

In conclusion, the Carrier 38VYX130 and 38VYX110 are exceptional choices for those looking for efficient, reliable, and quiet air conditioning systems. With their advanced technologies and commitment to sustainability, these models are set to provide superior comfort for years to come.