Oneida Air Systems Super Dust Gorilla manual VIII. Filter Assembly, External 39 Filter Assembly

Page 10

VIII. Filter Assembly

Before attaching filter, you must first carefully pull foam silencer on to end of plenum, pushing black plastic end against flange plate. It is a tight fit.

External 39” Filter Assembly

*Silencer Included.

1.Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1

2.If Filter requires additional support. Use the plate at the top of the filter to support the filter assembly.

Note: If filter cartridge is located away from the cyclone and motor, additional square-to-round connectors and pipe can be purchased.

The

GORILLA

Silencer

Filter

Fig. 1

Gasket

 

 

Material

(4)

3/8” x 1” Bolts

 

(8)

Washers

 

(4)

Serrated Nuts

 

For Filter cleaning instructions and

Dust Pan clipping instructions, see pg. 11.

Rod

Brace

Washer

Wing Nut

Dust Bin

Dust Pan Clips (3)

No Filter Assembly

1.Exhaust air to exterior of building. Mount directly at the hole in exterior wall or use a square-to-round transition and ductwork to vent air to exterior.

Option -

* Exhaust Diverter - Can be used either up or down

* Only usable on No Filter.

The

GORILLA

Note: Do not return exhaust air to the shop unless filter media is added.

Caution:

If exhaust air is vented outside you must provide make up / return air.

Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances.

Caution: Rotating blades! Keep hands clear. Keep people away from exhaust.

9

2HP Super Dust Gorilla Owner’s Manual c O.A.S. 2007

Image 10
Contents Gorilla Table of Contents System Start-Up Information II hp Dust Gorilla Configurations External Cartridge Filter Silencer Included with FilterIII. General Specifications & Fan Performance Curves 2hp Super Dust Gorilla SystemIV. Dimensions For Minimum Mounting Heights w/ 39 FilterGeneral Assembly XGK020105 Systems For AllVI. General Assembly Instructions VII. Bracket Assembly VIII. Filter Assembly External 39 Filter AssemblyIX. Filter Maintenance External Filter Cartridge Cleaning IntervalsDirections for Cleaning External Filter Compressed air from outsideXI. Wiring Diagram for Magnetic Starter 220v XII. Troubleshooting XIII. Fire Hazards Read Before Installing and Operating Oneida Collectors are designed for Wood Dust onlyChecking in Order Limited WarrantyXIV. Terms and Conditions Delivery Risk of LossXV. Stand Assembly RightXVI. Accessories XVII. Fan Motor Maintenance Service Conditions Lubrication Interval MultiplierXVIII. Remote Wiring Diagram Square D Telemecanique Mag StartersMounting Instructions