Optional - XIX. Filter Efficiency Gauge Mounting Instructions

Rectangular Plenum

Air Flow

to Filter

Can be

0

1

2

3

4

 

 

attached

5

INCHES W.C.

up to 8’

 

away.

 

OR

Mounting Instructions

1.Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not accessible. Refer to drawings for location of brass static pressure tube.

2.Refer to instructions provided with gauge for mounting to bracket.

3.Mount gauge up to 8’ away, mounting it closer will not affect reading.

4.Connect clear tubing from brass static pressure tube to the port labeled “high” on the back of the pressure gauge.

5.Make sure the tubing is not crushed or kinked along its entire length, cut shorter if necessary.

Gauge Reading Instructions

1.Gauge may need to be zeroed. Follow the instructions provided with pressure gauge.

2.Take the initial reading with cleaned filter(s) and the typical number of blast gates open in normal operation.

3.Always read the gauge with the same number of gates open. The more gates open, the higher the pressure reading on the gauge.

4.When the gauge rises to 3”, it’s time to clean your filter(s).

Elbow Plenum

(Side View)

Air Flow to Filter

After many cleaning cycles, a filter’s pressure will rise after each cleaning. An older filter does not get as clean as a new filter.

20

2HP Dust Gorilla Owner’s Manual c O.A.S. 2007

Image 21
Contents Gorilla Table of Contents System Start-Up Information External Cartridge Filter Silencer Included with Filter II hp Dust Gorilla Configurations2hp Super Dust Gorilla System III. General Specifications & Fan Performance CurvesFor Minimum Mounting Heights w/ 39 Filter IV. DimensionsSystems For All General Assembly XGK020105VI. General Assembly Instructions VII. Bracket Assembly External 39 Filter Assembly VIII. Filter AssemblyExternal Filter Cartridge Cleaning Intervals IX. Filter MaintenanceCompressed air from outside Directions for Cleaning External FilterXI. Wiring Diagram for Magnetic Starter 220v XII. Troubleshooting Oneida Collectors are designed for Wood Dust only XIII. Fire Hazards Read Before Installing and OperatingXIV. Terms and Conditions Limited WarrantyChecking in Order Delivery Risk of LossRight XV. Stand AssemblyXVI. Accessories Service Conditions Lubrication Interval Multiplier XVII. Fan Motor MaintenanceSquare D Telemecanique Mag Starters XVIII. Remote Wiring DiagramMounting Instructions