1.You must determine the direction the fan outlet will point to proceed with this mounting assembly. The collector will seem quieter if the outlet is aimed away from the area people tend to work. Slots in the brackets are .406” x 1.00”

Note: Bolts included to mount bracket to collector. Hardware NOT included to mount to wall.

2.Hold bracket against wall with top of plate at 56”. Mark where mounting holes fall. Mount wall bracket. For wall mounting, the bolt centers on the brackets are at 16”to accomodate most wall stud spacing. See Fig. 1 & 2. Use a Level to ensure straightness.

3.Attach bracket to wall with lag screws, concrete anchors, or other suitable hardware. See Fig. 2 & 3. Note: When installing the brackets on a concrete wall, mount 2 x 4’s between wall and brackets to stabilize and dampen vibration.

4.Position Angle Ring around top of cone over bracket. Line up one hole in Ring with hole in each bracket at desired rotation of outlet. If rotation you desire does not correspond to an existing hole in Angle Ring, drill new ones. Use three 3/8” bolts (included) with washers & lock washers to secure the fan. See Fig. 4.

5.Attach tightly with bolts. See Fig. 4.

1

 

 

24.25”

 

16”

 

.406” x 1.00”

 

16”

12 Ga.

 

2

Level

 

56” to top of plate.

4

Distance tor minimum

 

mounting height.

3

Note: Please do not install an Oneida Dust Collection System alone. Competent assistance is advisable. Units are heavy!

8

2HP Super Dust Gorilla Owner’s Manual c O.A.S. 2007

Image 9
Contents Gorilla Table of Contents System Start-Up Information External Cartridge Filter Silencer Included with Filter II hp Dust Gorilla Configurations2hp Super Dust Gorilla System III. General Specifications & Fan Performance CurvesFor Minimum Mounting Heights w/ 39 Filter IV. DimensionsSystems For All General Assembly XGK020105VI. General Assembly Instructions VII. Bracket Assembly External 39 Filter Assembly VIII. Filter AssemblyExternal Filter Cartridge Cleaning Intervals IX. Filter MaintenanceCompressed air from outside Directions for Cleaning External FilterXI. Wiring Diagram for Magnetic Starter 220v XII. Troubleshooting Oneida Collectors are designed for Wood Dust only XIII. Fire Hazards Read Before Installing and OperatingXIV. Terms and Conditions Limited WarrantyChecking in Order Delivery Risk of LossRight XV. Stand AssemblyXVI. Accessories Service Conditions Lubrication Interval Multiplier XVII. Fan Motor MaintenanceSquare D Telemecanique Mag Starters XVIII. Remote Wiring DiagramMounting Instructions