XI. Wiring Diagram for Magnetic Starter (220v, 1 ** )*
Always use a licensed, professional electrician.
Dedicated Receptacle Fed from 2 Pole Dedicated Circuit Breaker,
I
Motor | O |
Baldor 2hp |
|
Catalog |
|
#VL3515T |
|
Magnetic Starter -
Mount Close to Collector
6’ Long Type SJT
14 AWG Power Cord
*Note: Motor Starter supplied with system is for 220v only.
Open access cover on the Overload.
Note: Overload must be set or nuisance tripping may occur.
Set the overload amperage dial for the SFA* amperage of your motor. The SFA* value can be found below: SFA = 12.1
(FLA 11.5)
Note: This Dust Collector is
Optional Remote Controller diagram pg. 19
*SFA - Service Factor Amperage
*FLA - Full Load Amperage
*Starter will not operate at any other voltages.
**Starter is shown configured for 1O but can also be used for 2hp, 3O motors.
12
2HP Super Dust Gorilla Owner’s Manual c O.A.S. 2007