VI. General Assembly Instructions (Cont.)

7. Set up Fan/Blower

Square

CAUTION

All moving parts must have guards to protect personnel. Safety requirements vary, so the number and type of guards needed to meet company, local and OSHA standards must be determined and specified by the user. Never start a fan without having all safety guards installed. Check regularly for damaged or missing guards and do not operate any fan with guards removed. Fans can also become dangerous because of potential windmilling, even though all electrical power is disconnected. Always block the rotating assembly before working on any moving parts.

Fan Outlet - Connect to Plenum Box

to

Round

Fan

Inlet -

Connect

to top of

Cyclone

Fan Outlet - Square to round transition for fan outlet does not come with installation hardware. Drill holes, bolt screw, or pop rivet to fan outlet, seal with silicone. Make sure pulley cover and shaft guard are in place before operation.

8.If applicable, connect silencer to square-to-round transition.

9.Connect ductwork from fan inlet to top of Cyclone Barrel.

10.Set up Plenums according to height requirements for type.

- Instructions for Cartridge Filters

Clamp filter cartridges to plenum, then clamp dust bins to cartridges.

External Filter Cartridge Cleaning Intervals

Silencer

Square

to

Round

Cartridge

Filters

When unit is turned off, use compressed air to blow dust off from exterior of filter. Hold nozzle at least 8” away from filter pleats*. Do not remove bottom dust pan before or during the blow-off process! Let dust settle into dust pan. Unclip and dump out dust. Filter removal is not required. You can also run your fingers around the filter pleats to knock material down.

- Instructions for Tube Filters - See next page.

- Instructions for build your own plenum - See next page.

11. Connect ductwork between Fan/Blower outlet or Silencer and plenum.

10

10 HP Pulley Drive Owner’s Manual c O.A.S. 2007

Image 11
Contents HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Table of Contents System Start-Up Information No Filter Vent Outside II hp Pulley Drive ConfigurationsOptional Items Filter Media 10hp Fan CurvesCyclone C-3500 System Packages IncludeIV. Dimensions External Tube Filters 29 1/8 IV. Dimensions External Cartridge Filters Cyclone Stand w/ 55 Gal. Drum STZ350055 Configuration Examples Hole in ring if needed for your orientation VI. General Assembly InstructionsSet up Fan/Blower OAS Galvanized Plenum Box VII. External Filter Bag AssemblyWiring should always be done by a licensed electrician XII. Fan / Blower Wiring DiagramMaintenance of Fan / Blower IX. Fan / Blower MaintenanceBelt Drive Maintenance of Fan / BlowerMultiple Drums AccessoriesFilters filling with large chips and excessive dust XII. TroubleshootingMotor Overheating Poor Dust Pick-Up at Woodworking MachinesXII. Fire Hazards Read Before Installing and Operating Delivery Risk of Loss Limited WarrantyXIII. Terms and Conditions Checking in OrderExternal Filter can be cleaned using the following methods XIV. Directions for Cleaning External FilterAir Flow to Filter Mounting InstructionsStart / Stop Pushbutton Overload Amperage Dial NEC Nfpa