Oneida Air Systems 10 HP 10hp Fan Curves, Cyclone C-3500, System Packages Include, Dust Bins

Page 5

III. General Specifications & Fan Performance Curves

Cyclone C-3500

Full welded exterior

Main body, cone and inlet: 16 ga. galv. Flanged 12” dia. Inlet; Flanged 13” dia. Outlet 80” high

14” rolled steel flange discharge

36” dia. rolled steel flange for mounting

System Packages Include:

10hp Fan / Blower

Made in USA NYB 224 DH Arrangement 10

10 horsepower, Pulley drive with weather/shaft guard TECO - Westinghouse TEFC 60 Hz 10hp Motor

Three Phase: 230/460v 24/12A (Usable on 208v 25.9 A)

Fan Wheel Dia.: 22.625”

3300 CFM @ 12” Static Pressure

Optional Items:

Filter Media

Exterior Cartridge Filters

10hp - 3 Cartridges - 390 Sq. Ft.

Spun-Bonded Polyester BIA ZH1/487 Test - Rated C Captures 99.99% of test material over 20 microns Captures 99.9% of test material between 0.2 - 2.0 microns @ 11 fpm face velocity

Exterior Tube Filters

10hp - 10 Tube Filters

Needle Felted Media BIA ZH1/487 Test - Rated G Captures 99.99% of test material over 20 microns Captures 99.5% of test material between 0.2 - 2.0 microns @ 11 fpm face velocity

Dust Bins

55 Gal. Steel Drum

Other large dust bins available

Angle Iron Wall Mount Brackets

Angle Iron Stand

Plenum Box - 10 or 14 hole ring thimble plenum box to hold Tube Filters. Silencer - For fan / blower outlet to 13” I.D., will reduce noise level.

Magnetic Motor Starters

Rotary Air-Loc

10hp Fan Curves

Wg.)

10hp Performance Curve

 

 

 

 

 

 

 

 

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(In.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static

5.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1000

2000

3000

4000

5000

6000

7000

WARNING!

This fan has moving parts that can cause serious injury. Read the installation and maintenance instructions and the AMCA Safety Practices manual before starting maintenance or operating.

During Operation

1.Keep body, hands and objects away from the inlet, outlet and other moving parts of the fan such as belts, pulleys and shafts.

2.Do not operate at excessive speeds or temperatures.

Before starting maintenance work:

Lock power supply in off position and immobilize fan wheel.

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

Input

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

10

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

(bhp)

 

 

 

 

 

 

 

 

 

 

 

 

2.5

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

8000

9000

 

Static pressure and volume together determine

Volume Flow Rate (CFM) Performance -

a fan’s performance. Several factors, such as Horsepower - layout of ductwork and diameter of openings,

can affect a fan’s performance.

4

10 HP Industrial Systems Owner’s Manual c O.A.S. 2007

Image 5
Contents HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Table of Contents System Start-Up Information No Filter Vent Outside II hp Pulley Drive ConfigurationsCyclone C-3500 10hp Fan CurvesSystem Packages Include Optional Items Filter MediaIV. Dimensions External Tube Filters 29 1/8 IV. Dimensions External Cartridge FiltersCyclone Stand w/ 55 Gal. Drum STZ350055 Configuration Examples Hole in ring if needed for your orientation VI. General Assembly InstructionsSet up Fan/Blower OAS Galvanized Plenum Box VII. External Filter Bag AssemblyWiring should always be done by a licensed electrician XII. Fan / Blower Wiring DiagramMaintenance of Fan / Blower IX. Fan / Blower MaintenanceBelt Drive Maintenance of Fan / BlowerMultiple Drums AccessoriesMotor Overheating XII. TroubleshootingPoor Dust Pick-Up at Woodworking Machines Filters filling with large chips and excessive dustXII. Fire Hazards Read Before Installing and Operating XIII. Terms and Conditions Limited WarrantyChecking in Order Delivery Risk of LossExternal Filter can be cleaned using the following methods XIV. Directions for Cleaning External FilterAir Flow to Filter Mounting InstructionsStart / Stop Pushbutton Overload Amperage Dial NEC Nfpa