Oneida Air Systems 10 HP manual Overload Amperage Dial

Page 23

Open access cover on the overload, then set the overload amperage dial to match the FLA amperage of your motor. The FLA value can be found on your motor nameplate.

Overload

Amperage

Dial

Be sure you have the proper voltage available for your Starter’s Power & Control Circuit (Control circuit controls Contactor Coil in Starter). Coil voltage is/can be independent from the line voltage that runs your motor. Customers may desire an alternative Contactor Coil voltage to connect a Starter to a low voltage control circuit. Most OAS Starters are shipped with 240v coils.

Plug the Start/Stop Push-Button Assembly into keyed receptacle. (As shown below.)

Run power to the starter and from the starter to your motor. See the manufacturer instructions for more details.

The Power Circuit connected to the Starter should be fed from a dedicated circuit breaker or disconnect with fuses. Don’t connect any branch circuits to the Mag Starter Power Circuit. The overcurrent protection (circuit breaker or fuse*) for the Starter Power Circuit is to be sized per Article 430.32 of the NEC.

*Use time delay fuses rated for motor circuits.

 

22

 

 

 

10 HP Pulley Drive Owner’s Manual c O.A.S. 2007

Image 23
Contents HP NYB Pulley/Belt Drive Cyclonic Dust Collectors Table of Contents System Start-Up Information No Filter Vent Outside II hp Pulley Drive ConfigurationsOptional Items Filter Media 10hp Fan CurvesCyclone C-3500 System Packages IncludeIV. Dimensions External Tube Filters 29 1/8 IV. Dimensions External Cartridge FiltersCyclone Stand w/ 55 Gal. Drum STZ350055 Configuration Examples Hole in ring if needed for your orientation VI. General Assembly InstructionsSet up Fan/Blower OAS Galvanized Plenum Box VII. External Filter Bag AssemblyWiring should always be done by a licensed electrician XII. Fan / Blower Wiring DiagramMaintenance of Fan / Blower IX. Fan / Blower MaintenanceBelt Drive Maintenance of Fan / BlowerMultiple Drums AccessoriesFilters filling with large chips and excessive dust XII. TroubleshootingMotor Overheating Poor Dust Pick-Up at Woodworking MachinesXII. Fire Hazards Read Before Installing and Operating Delivery Risk of Loss Limited WarrantyXIII. Terms and Conditions Checking in Order External Filter can be cleaned using the following methods XIV. Directions for Cleaning External FilterAir Flow to Filter Mounting InstructionsStart / Stop Pushbutton Overload Amperage Dial NEC Nfpa