SECTION 2: CIRCUIT REQUIREMENTS

110V Wiring

Your Model G1032 Dust Collector operates ideal- ly at 110V, single phase power. The 1 HP motor will draw roughly 8 amps at 110 volts. These loads are not excessive, but if you operate your machine on any circuit that is already close to capacity, it might blow a fuse or trip a circuit breaker. If an unusual load does not exist, and power failure still occurs, consult a qualified elec- trician. Otherwise, consider a dedicated circuit for your machine.

A 110V plug is provided with the G1032.

In the case of 220V operation, please call the service department for further information.

Grounding

CAUTION: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an equipment-grounding conductor. The grounding conductor must be connected to the grounding pin on the plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper connections of the electrical-grounding conductor can result in risk of electric shock. The conductor with green or green and yellow striped insulation is the electrical-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.

Under no circumstances should the grounding pin from any three-pronged plug be removed. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Check with a qualified electrician or one of our service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded. Use only 3-wire extension cords that have 3-prong ground- ing type plugs and 3-hole receptacles that accept the tool’s plug. FIgure 1.

Repair or replace damaged or worn cord immedi- ately.

Figure 1.

-4-

G1032 Dust Collector

Image 6
Contents Dust Collector G1032 Dust Collector Table Of Contents Safety Safety Instructions For Power ToolsAdditional Safety Instructions For Dust Collectors 110V Wiring Circuit RequirementsGrounding General Information Unpacking Piece Inventory Site Considerations Assembly Beginning Assembly BaseSupport Column Fan / Motor CollectorBags Test Run Set Up OperationsMobileStationary System Grounding Maintenance GeneralLubricationClosure Castor Grizzly Model G1032 Dust Collector Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC