Grizzly G5954 owner manual Circuit Requirements, 220V Single-Phase

Page 11

SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G5954 motor draws the following amps under maximum load:

Motor Draw at 220V

34 Amps

Circuit Requirements

We recommend using a dedicated circuit for this machine. You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amper- age without consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

220V Circuit........................................... 50 Amps

Connection Type (Figure 1)

220V

Locking Shut-off Switch

G5954 5HP Dust Collector

Figure 1. Locking shut-off switch.

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock. The grounding wire in the power cord must be properly connect- ed to the grounding pole in the locking shut-off switch; likewise, the locking shut-off switch must be properly installed and grounded. All electrical connections must be made in accordance with local codes and ordinances.

Electrocution or fire could result if this machine is not grounded correctly or if your electrical con- figuration does not com- ply with local and state codes. Ensure compliance by checking with a quali- fied electrician!

-9-

Image 11
Contents Model G5954 HP Dust Collector Page Table of Contents Contact Info IntroductionForeword Machine Data Sheet 21.9 cu. ft Max CFM Max SP Volts Amps Inlet Dia Impeller Dia Static Pressure Inch/H2O Safety Instructions for Machinery SafetyAlways Lock Mobile Bases if Used Before Operating Machinery Additional Safety for Dust Collectors Circuit Requirements 220V Single-PhaseOther Components and Hardware Qty SET UPInventory Small Component Inventory Figure QtyWorking Clearances CleaningSite Considerations Components and Hardware Needed Qty To attach the collectors to the motor/fan assemblyBase and Motor/Fan CollectorCollection Bags To set up the collecton bagsMetal Duct Operation Safety GeneralOperations Duct MaterialFlexible Duct Plastic DuctSketch a Basic Duct Layout System DesignDecide Who Will Design Sketch Your Shop LayoutMachine Determine Required CFM of Each MachineMachine Approximate Total CFM Branch Line Size Determining Main Line Duct SizeDetermining Branch Line Duct Size Fitting 90˚ 45˚ Dia Elbow WyeY Calculating Duct ResistanceDuct Approximate Dia Loss Per FootFlex-hose grounded to machine System GroundingReducers & Adapters AccessoriesElectrical Components Model G5954 Switch WiringWiring Diagram G5954 Parts Breakdown Description G5954 Parts ListWarranty and Returns Page Page