Grizzly G5954 owner manual Collection Bags, To set up the collecton bags

Page 15

3.Press-fit the 4-in-1 inlet adapter onto the col- lector inlet, as shown in Figure 8.

Figure 8. Installing 4-in-1 inlet adapter.

Collection Bags

 

Components and Hardware Needed:

Qty

Upper Bag Supports

2

Upper Bag Support Extenders

2

Lower Support

1

Lower Support Foot Pad

1

Upper Collection Bags

2

Lower Collection Bags

2

Flange Bolts 516-18 x 34

6

Flange Bolts 14-20 x 12

4

To set up the collecton bags:

 

1.Screw the lower support foot pad onto the bottom of the lower support.

2.Attach the lower support to the Collector using two 516-18 x 34 hex bolts.

G5954 5HP Dust Collector

3.Attach each upper bag support to an upper bag support extender using the 14-20 x 12 hex bolts.

4.Attach each upper bag support to the Collector using two 516-18 x 34 hex bolts.

5.Hang an upper bag from an upper bag sup- port extender.

6.Pull the bottom of the upper bag over the lip of the collector below it, and fasten it in place with a bag clamp, as shown in Figure 9.

Figure 9. Fitting bag onto collector.

7.Repeat Steps 4 & 5 for the other upper bag.

8.Fit a lower bag over the bottom lip of the collector, and fasten it in place with a bag clamp.

9.Repeat Step 6 for the other lower bag.

-13-

Image 15
Contents Model G5954 HP Dust Collector Page Table of Contents Introduction ForewordContact Info Machine Data Sheet 21.9 cu. ft Max CFM Max SP Volts Amps Inlet Dia Impeller Dia Static Pressure Inch/H2OSafety Instructions for Machinery SafetyAlways Lock Mobile Bases if Used Before Operating Machinery Additional Safety for Dust Collectors Circuit Requirements 220V Single-Phase Other Components and Hardware Qty SET UP Inventory Small Component Inventory Figure QtyCleaning Site ConsiderationsWorking Clearances Components and Hardware Needed Qty To attach the collectors to the motor/fan assemblyBase and Motor/Fan CollectorCollection Bags To set up the collecton bagsMetal Duct Operation Safety GeneralOperations Duct MaterialFlexible Duct Plastic DuctSketch a Basic Duct Layout System DesignDecide Who Will Design Sketch Your Shop LayoutDetermine Required CFM of Each Machine Machine ApproximateMachine Determining Main Line Duct Size Determining Branch Line Duct SizeTotal CFM Branch Line Size Fitting 90˚ 45˚ Dia Elbow WyeY Calculating Duct ResistanceDuct Approximate Dia Loss Per FootFlex-hose grounded to machine System GroundingReducers & Adapters AccessoriesElectrical Components Model G5954 Switch WiringWiring Diagram G5954 Parts Breakdown Description G5954 Parts ListWarranty and Returns Page Page