Maintenance
Never perform maintenance on this machine before turning switch off and removing plug from power source. Failure to comply may cause serious injury!
Cleaning the Filter Bag – DC-1100BK and DC-1100MK
Wearing a particle mask or respirator for protection against fine dust particles during cleaning is highly recommended.
During first use and after cleaning, the filter bag may allow some dust to escape. This is normal and will stop after a short period of time.
Clean both the filter and collector bags frequently to keep the collector's performance at its optimum. To clean:
1.Disconnect the machine from the power source.
2.Unhook the filter bag from the hanger and shake the bag so that the majority of the dust falls into the collector bag.
3.Loosen the retaining strap, and remove the filter bag from the housing.
4.Turn the bag inside out and clean.
5.Turn the bag outside in and
Removing the Collector Bag–DC-1100BK
1.Disconnect the machine from the power source.
2.Remove the collector bag by pushing the ring of the collector bag upwards and pulling the bag out at an angle.
3.Empty the contents into an appropriate container.
4.Turn the bag inside out and clean.
5.Turn the bag outside in and insert into the housing.
To replace the collector bag, refer to Collector Bag Installation on page 11.
Use the proper type hose to connect the dust collector to the machine being operated. Dryer vent hose is not acceptable for this purpose. Contact your nearest JET distributor for the full line of JET Dust Collector Hoses and Accessories. Customize your installation and obtain maximum performance with JET dust hoods, hoses, clamps, fittings, and blast gates.
Cleaning the Filter – DC-1100CK
Never perform maintenance on this machine before turning switch off and removing plug from power source. Failure to comply may cause serious injury!
Clean both the canister filter and collector bags frequently to keep the collector's performance at its optimum.
To clean the filter, turn the handle a couple of rotations so the dust falls into the collection bag.
Removing the Collector Bag–DC-1100CK and DC-1100MK
Wearing a particle mask or respirator for protection against fine dust particles during cleaning is highly recommended.
1.Disconnect the machine from the power source outlet.
2.Remove the collector bag by pushing the ring of the collector bag upwards at an angle and pulling the bag and snap ring out.
3.Empty the contents into an appropriate container.
To replace the collector bag, refer to the Collector Bag Installation on page 12.
Motor
Make frequent inspections of the motor fan and blow out (with low pressure air hose) or vacuum any accumulation of foreign material in order to maintain normal motor ventilation.
Connecting the Dust Collector to a Machine
Use the proper type hose to connect the dust collector to the machine being operated. Dryer vent hose is not acceptable for this purpose. Contact your nearest JET distributor for the full line of JET Dust Collector Hoses and Accessories. Customize your installation and obtain maximum performance with JET dust hoods, hoses, clamps, fittings, and blast gates.
Grounding the Dust Collection System
The dust collection system includes the dust collector and the hose, or ductwork you use to connect the tools. The dust collector is grounded through the ground wire in the cord. The hose or ductwork you use to connect the tool to the dust collector must also be grounded.
15