Delta AP300 instruction manual Power Connections, Motor Specifications, Grounding Instructions

Page 6

POWER CONNECTIONS

A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3- prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the machine. All line connections should make good contact. Running on low voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

MOTOR SPECIFICATIONS

Your machine is wired for 120 volts, 60 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the “OFF” position.

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK.

1. All grounded, cord-connected machines:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding conductor can result in risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment- grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that accept the machine’s plug, as shown in Fig. A.

Repair or replace damaged or worn cord immediately.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

2.Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than 150 volts:

If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like the adapter illustrated in Fig. B, may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.

IN ALL CASES, MAKE CERTAIN THE R E C E P TA C L E I N Q U E S T I O N I S P R O P E R LY GROUNDED. IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

6

Image 6
Contents Portable Single-Stage Dust Collector Table of Contents Important Safety InstructionsSafety Guidelines Definitions California PropositionGeneral Safety Rules Important Safety InstructionsAdditional Specific Safety Rules Failure to Follow These Rules MAY Result in Serious InjuryPower Connections Motor SpecificationsGrounding Instructions Volt Single Phase Operation Extension CordsCarton Contents Functional DescriptionCasters AssemblyAssembly Tools Required Exhaust FlangeDust Port Tube and Connector to Dust Collector Body Disconnect machine from power sourceAlign the two holes in the intake support angle brace Vacuum Hose to Dust Collector Dust BAG to Dust Collector Locking Switch OFF Position OperationStarting and Stopping Dust Collector Machine USE Troubleshooting Transportation and StorageMaintenance Keep Machine CleanFailure to Start Service AccessoriesWarranty Recolector de Polvo Portátil de Etapa Sencilla Instrucciones DE Seguridad Importantes Pautas DE SEGURIDAD/DEFINICIONESNormas Generales DE Seguridad EL USO DE Esta Herramienta Puede Generar Y DispersarNormas Específicas Adicionales DE Seguridad Guarde Estas InstruccionesConexiones a LA Fuente DE Alimentación Especificaciones DEL MotorInstrucciones DE Conexión a Tierra Cordones DE Extensión Cordón DE Extensión DE Calibre MínimoPrologo Descripción FuncionalContenido DE Carton Desempaquetado Y LimpiezaRuedecillas EnsamblajeHerramientas DE Ensamblaje Requeridas DE LA Brida DE LA SalidaPage Page DE UNA Manguera DE Aspiración EN EL Colector DE Polvo DE LA Bolsa Para Polvo EN EL Colector DE Polvo Operación Arranque Y Parada DEL Colector DE PolvoFijación DEL Interruptor EN LA Posición DE Apagado Utilizar LA Maquina Transporte Y Almacenamiento Localizacion DE Fallas Mantenimiento Mantenga LAS Herramientas LimpiasFalla DE Ponerse EN Marcha Servicio AccesoriosGarantia Canadian PORTER-CABLE Delta Service Centers

AP300 specifications

The Delta AP300 is a state-of-the-art air purification system designed to enhance indoor air quality through advanced filtration technology and smart features. This device is engineered to meet the needs of both residential and commercial spaces, ensuring optimal air cleanliness while providing an array of user-friendly functionalities.

One of the standout features of the Delta AP300 is its three-stage filtration system. The first stage incorporates a pre-filter that captures larger particles such as dust and pet dander, prolonging the life of subsequent filters. The second stage utilizes a true HEPA filter, which is capable of eliminating 99.97% of airborne pollutants, including pollen, mold spores, and fine particulate matter. The final stage consists of an activated carbon filter, which is specifically designed to neutralize odors and volatile organic compounds (VOCs). Together, these filters ensure the air is free of harmful contaminants, making it ideal for allergy sufferers and those concerned about indoor air quality.

Equipped with advanced sensing technology, the Delta AP300 can automatically adjust its purification levels based on real-time air quality readings. Its built-in air quality sensor detects changes in the environment, allowing the unit to operate efficiently and deliver clean air when it matters most. This intelligence not only optimizes performance but also enhances energy efficiency, reducing overall operational costs.

The Delta AP300 also features a sleek and modern design, making it a stylish addition to any room. With its compact dimensions, it can easily fit into various spaces without occupying much room. The user interface is intuitive, featuring a clear LED display that indicates air quality status, filter replacement reminders, and fan speed settings.

Additionally, the Delta AP300 is designed for quiet operation, making it suitable for use in bedrooms or nurseries without causing disturbance. Its multiple fan speeds allow users to customize the airflow according to their preferences.

In summary, the Delta AP300 stands out in the air purification market due to its powerful filtration capabilities, intelligent sensing technology, and user-friendly design. It is an excellent choice for anyone looking to significantly improve their indoor air quality while enjoying a range of modern features that cater to contemporary lifestyles.