Troubleshooting
Problem |
| Possible Causes |
| Likely Solutions |
Tool will not start. | 1. | Cord not connected. | 1. | Check that cord is plugged in. |
| 2. | No power at outlet. | 2. | Check power at outlet. If outlet is unpowered, |
|
|
|
| turn off tool and check circuit breaker. If |
|
|
|
| breaker is tripped, make sure circuit is right |
|
|
|
| capacity for tool and circuit has no other |
|
|
|
| loads. |
| 3. | Internal damage or wear. | 3. | Have technician service tool. |
|
| (Carbon brushes or switch, |
|
|
|
| for example.) |
|
|
Attachment is loose | 1. Holes on attachment not | 1. | Remove the attachment and | |
on the tool. |
| lined up with pins on Spindle. |
| making sure that the holes in the attachment |
|
|
|
| are secured over the pins on the Spindle. |
2.Cap screw not tight enough. 2. Remove the attachment and
|
|
|
| |
Tool operates slowly. Extension cord too long or wire | Eliminate use of extension cord. If an extension | |||
| size too small. | cord is needed, use shorter/heavier gauge cord. | ||
|
|
| See Extension Cords in GROUNDING section. | |
Performance | 1. | Attachment dull or damaged. | 1. | Keep cutting accessories sharp. Replace as |
decreases over time. |
|
|
| needed. |
| 2. | Carbon brushes worn or | 2. | Have qualified technician replace brushes. |
|
| damaged. |
|
|
Excessive noise or | Internal damage or wear. | Have technician service tool. | ||
rattling. | (Carbon brushes or bearings, |
|
| |
| for example.) |
|
| |
Overheating. | 1. | Forcing tool to work too fast. | 1. | Allow tool to work at its own rate. |
2.Attachment dull or damaged. 2. Keep cutting accessories sharp. Replace as needed.
3. | Blocked motor housing | 3. | Wear |
| vents. |
| |
|
|
| blowing dust out of motor using compressed |
|
|
| air. |
4. | Motor being strained by long | 4. | Eliminate use of extension cord. If an |
| or small diameter extension |
| extension cord is needed, use one with the |
| cord. |
| proper diameter for its length and load. See |
|
|
| Extension Cords in GROUNDING section. |
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.
REV 10e
SKU 67256 | For technical questions, please call | Page 12 |