Chicago Electric 67256 Troubleshooting, Problem Possible Causes Likely Solutions

Page 12

Troubleshooting

Problem

 

Possible Causes

 

Likely Solutions

Tool will not start.

1.

Cord not connected.

1.

Check that cord is plugged in.

 

2.

No power at outlet.

2.

Check power at outlet. If outlet is unpowered,

 

 

 

 

turn off tool and check circuit breaker. If

 

 

 

 

breaker is tripped, make sure circuit is right

 

 

 

 

capacity for tool and circuit has no other

 

 

 

 

loads.

 

3.

Internal damage or wear.

3.

Have technician service tool.

 

 

(Carbon brushes or switch,

 

 

 

 

for example.)

 

 

Attachment is loose

1. Holes on attachment not

1.

Remove the attachment and re-mount,

on the tool.

 

lined up with pins on Spindle.

 

making sure that the holes in the attachment

 

 

 

 

are secured over the pins on the Spindle.

2.Cap screw not tight enough. 2. Remove the attachment and re-mount, making sure that the holes in the attachment are secured over the pins on the Spindle, then tighten the Cap Screw to at least 10

 

 

 

 

ft-lbs.

Tool operates slowly. Extension cord too long or wire

Eliminate use of extension cord. If an extension

 

size too small.

cord is needed, use shorter/heavier gauge cord.

 

 

 

See Extension Cords in GROUNDING section.

Performance

1.

Attachment dull or damaged.

1.

Keep cutting accessories sharp. Replace as

decreases over time.

 

 

 

needed.

 

2.

Carbon brushes worn or

2.

Have qualified technician replace brushes.

 

 

damaged.

 

 

Excessive noise or

Internal damage or wear.

Have technician service tool.

rattling.

(Carbon brushes or bearings,

 

 

 

for example.)

 

 

Overheating.

1.

Forcing tool to work too fast.

1.

Allow tool to work at its own rate.

2.Attachment dull or damaged. 2. Keep cutting accessories sharp. Replace as needed.

3.

Blocked motor housing

3.

Wear ANSI-approved safety goggles and

 

vents.

 

NIOSH-approved dust mask/respirator while

 

 

 

blowing dust out of motor using compressed

 

 

 

air.

4.

Motor being strained by long

4.

Eliminate use of extension cord. If an

 

or small diameter extension

 

extension cord is needed, use one with the

 

cord.

 

proper diameter for its length and load. See

 

 

 

Extension Cords in GROUNDING section.

Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.

REV 10e

SKU 67256

For technical questions, please call 1-800-444-3353.

Page 12

Image 12
Contents MULTI-FUNCTION Power Tool For technical questions or replacement parts, please callGeneral Safety Warnings Save This ManualFor technical questions, please call Gfci reduces the risk of electric shock Specific Safety Warnings Vibration Safety Grounding Double Insulated Tools Tools With Two Prong PlugsExtension Cords See Outlets for 2-Prong PlugSpecifications UnpackingSee Table a Assembly Instructions ComponentsSee Figure B Figure D Work Piece and Work Area Set Up Operating InstructionsGeneral Operating Instructions Maintenance Servicing It must be replaced only by a qualified service technicianPlease Read Following Carefully SKU For technical questions, please callTroubleshooting Problem Possible Causes Likely SolutionsParts List and Assembly diagram Part Description QtyLimited 90 DAY Warranty Record Product’s Serial Number Here