Carrier 38AN,BK specifications InstallFan Coil Unit Onto Mounting Bracket, Indoor and Outdoor Unit

Page 13

outdoorunit.Forinstallationsimplicity,thefield- suppliedconductorshouldbeblack,white,andbarecop- perfor009applicationsandblack,red,andbarecopper for012applications.

6.Wiretheoutdoorunitsasfollows:

Cooling-Only,Size009Systems: Connectthe2blackleadstoterminalblocklocationL. Connectthe2whiteleadstoterminalblocklocationN. Connectthe2barecoppergroundleadstotheterminal blocklocationG.Connecttheredleadtoterminalblock location3.SeeFig.11.

Cooling-Only,Size012Systems: Connectthe2blackleadsto terminalblocklocation L1.Connectthe2redleadstoterminalblocklocation L2.Connectthe2barecoppergroundleadstoterminal blocklocationG.Connecttheyellowleadtoterminal blocklocation3.SeeFig.11.

HeatPump,Size009Systems:

Connectthe2blackleadstoterminalblocklocationL.

Connectthe2whiteleadstoterminalblocklocationN.

Connectthe2barecoppergroundleadstoterminalblock

locationG.Connecttheyellowleadtoterminalblock location3.Connecttheorangeleadtoterminalblock location1.Connectthegrayleadtoterminalblocklo- cation2.SeeFig.11.

SERVICE COVER

OUTDOOR UNIT

*The 012 heat pump units have the following terminal blockconnec-

tions: 1,2, 3, L1, L2, G, The cooling-onlyunitsare equivalent to their respective heat pump units,except the cooling-onlyunitsdo not have terminal block connections 1 and 2.

HeatPump,Size012Systems:

Connectthe2 blackleadstoterminalblocklocation L1.Connectthe2redleadstoterminalblocklocation L2.Connectthe2barecoppergroundleadstoterminal blocklocationG.Connecttheyellowleadtoterminal blocklocation3.Connecttheorangeleadtoterminal blocklocation1.Connectthegrayleadtoterminalblock location2.SeeFig. .11.

7.Connecttheotherendofthefield-supplied3-wirepower conductorthebranchcircuitdisconnect.

8.Replaceaccesscover.

Step 9 --InstallFan Coil Unit Onto Mounting

Bracket

I.Hook the fan coil unit onto the top of the mounting bracket. See Fig. 12.

2.Snap the fan coil unit onto the mounting bracket as shown in Fig. 12.

IMPORTANT: An audible snapping sound will be heard as the hook on the unit is secured into the

hole on the mounting bracket. Be sure unit is cor- rectly mounted.

TERMINAL BLOCK DETAIl.

(0C9 HEAT PUMP UNIT SHOWN)*

CONNECTION CABLE

INDOOR AND OUTDOOR UNIT

Fig. 11 --Electrical Connections

TOP

bI *_

,4b

<.::,.

MOUNTING .._.._/''_"

_,d--*

 

 

 

-,11"i---- 10 5/_ "--II

II--

10 518"-_

_

_

BRACKET.*.,:J

HOOK HOLE .'.,.:.:'

Fig. 12 --Mounting Fan Coil Unit to Bracket

13

Image 13
Contents Service Instructions System Indoor Outdoor Unit System Combinations for Indoor Outdoor UnitsCooling HeatingLii High Wall Unit Package ContentsPhysical Data, 40QNB Cooling Only High Wall Units Physical Data, 38AN Cooling Only Condensing UnitsUnit 38BK Physical Data, 38BK009,012 Outdoor Heat Pump UnitsRefrigerant Type Physical Data, 40QNEIH Heat Pump High Wall Units Operating WeightUnit Ciso,..5s Unit Weightabc 40QN Dimensional DrawingFig, 6 --Maximum System Line Lengths System Piston Guide Refrigerant ChargesMAX Hi--till/I/IRear Piping Size 009 Shown Wall Hole Location For Fan Coil Unit?q,ElldIi PR ,LI-1,II Flare Nut Tightening TorqueIj i Flare NUT Tube TorqueVoltagerange Compressor FAN Electric Heater DataLRA RLA FLA Service Cover Outdoor Unit InstallFan Coil Unit Onto Mounting BracketIndoor and Outdoor Unit START-UP Wireless Remote Controllers --A wireless remoteHeat Microprocessor Control Operation --This sysWill stop30secondsafterthecompressorstopsAfter Emer --Emergency Outdoorair TemperaturefCleaning and Maintenance Schedule To Install or Replace Remote Controller BatteriesTask Monthly Quarterly Yearly Indoor Unit To Clean Indoor Coil --To clean the coil, remove To Clean Condensate Drains-- Clean all drainsRemovecover SET TimeNO. of Quick System Fault LED Flashes SystemFault CodesProblem Potential Source Action Troubleshooting40QN Thermistor Properties Minimum Nominal Maximum Temp Thermistor Ohms Volts -- DCWall CAP Wireless CONTROLLER*AIRFLOWTo Opendrain IFM JEM-A Aging CAP CH Comp EMI FMC GNDOFM PCB PTC RCVFl I rl Control 38BK009 with 40QNE009 Heat Pump System Wiring Diagram Control PCB A55 Y Page

38AN,BK specifications

The Carrier 38AN,BK is a distinguished model in the world of air conditioning, known for its advanced features, innovative technologies, and exceptional performance. This air conditioning unit is particularly favored for residential and small commercial applications, offering a perfect blend of efficiency, reliability, and comfort.

One of the main features of the Carrier 38AN,BK is its high energy efficiency, which is crucial in today’s eco-conscious environment. With a Seasonal Energy Efficiency Ratio (SEER) rating that often exceeds industry standards, this unit ensures minimal energy consumption while providing powerful cooling capabilities. This not only contributes to lower utility bills but also reduces the overall carbon footprint.

The Carrier 38AN,BK employs advanced cooling technologies that make it a standout choice. One notable feature is its use of a scroll compressor, which operates with fewer moving parts than traditional models, resulting in reduced noise levels and enhanced durability. This compressor design also ensures a smoother operation, translating to consistent temperature control and a more comfortable indoor environment.

Another innovative technology incorporated in the Carrier 38AN,BK is the use of smart controls, allowing users to easily adjust settings and monitor performance through compatible smart devices. This feature adds convenience and flexibility, enabling homeowners to manage their home climate efficiently, even when they are away.

In terms of construction, the Carrier 38AN,BK’s robust design includes a galvanized steel cabinet that is resistant to corrosion and designed to withstand adverse weather conditions. This ensures longevity and reliable performance throughout the year. Additionally, the unit features advanced filtration systems that help improve indoor air quality by reducing allergens and pollutants, further enhancing user comfort.

Furthermore, the Carrier 38AN,BK is designed to operate quietly, making it an ideal choice for bedrooms and other quiet spaces. Its noise reduction features, combined with its energy-saving capabilities, position it as an attractive choice for a wide range of applications.

In summary, the Carrier 38AN,BK air conditioning unit excels in efficiency, advanced technologies, and user-friendly features. Its reliable design and quiet operation make it a top choice for anyone seeking effective and environmentally responsible cooling solutions. As both technology-savvy and eco-friendly, it meets the demands of modern homeowners while delivering exceptional comfort year-round.