Carrier 38AN,BK To Clean Condensate Drains-- Clean all drains, Removecover, SET Time

Page 19

To Clean Indoor Unit Front Panel -- If the front panel of the unit becomes dirty or smudged, wipe the out- side of the front panel with a soi_ dry cloth. If necessary, use a mild liquid detergent and wipe offcarefully with a dry cloth.

When cleaning the front panel, NEVER use water hot- ter than 105 F, and DO NOT pour water into the fan coil unit. Do not use abrasive or petroleum based clean- ers -- damage to unit appearance will result.

To Clean Indoor Coil --To clean the coil, remove in-

door unit front panel, and vacuum the coil fins. Use care not to bend or damage fins.

1

To Clean Outdoor Coil (Outdoor Unit)

Ffl g;L_TI1T[_

Some metal parts and sharp fins of ontdoor unit coil can cause personal injury during cleaning. Clean coil carefully.

To clean the outdoor coil:

I. Remove any dirt or obstruction from discharge opening.

2.Use garden hose to spray water on the coil. Debris that collects between coil fins inhibits heat transfer -- direct

the water spray between coil fins to flush out debris.

To Clean Condensate Drains-- Clean all drains and

drain pans at the start of each cooling season. Check the flow by pouring water into the drain.

REMOVECOVER

INSERT NEW BATTERIES

PRESS I-_'T']

NOTE: Be sure to insert new batteries correctly (as shown).

Fig. 18 --Installing or Replacing Batteries

v

HOUR /

 

"_"MINUTE

BUTTON

 

BUTTON

PRESS r_

SET TIME

PRESS i"_'i

Fig. 19 --Setting the Current Time

REMOVEFILTERVACUUMCLEAN

Fig. 20 -- Air Filter Maintenance

RINSE WITH WATER

19

Image 19
Contents Service Instructions Heating System Combinations for Indoor Outdoor UnitsSystem Indoor Outdoor Unit CoolingLii High Wall Unit Package ContentsPhysical Data, 40QNB Cooling Only High Wall Units Physical Data, 38AN Cooling Only Condensing UnitsUnit 38BK Physical Data, 38BK009,012 Outdoor Heat Pump UnitsRefrigerant Type Physical Data, 40QNEIH Heat Pump High Wall Units Operating WeightUnit Ciso,..5s Unit Weightabc 40QN Dimensional DrawingHi--till/I/I System Piston Guide Refrigerant ChargesFig, 6 --Maximum System Line Lengths MAXRear Piping Size 009 Shown Wall Hole Location For Fan Coil Unit?q,ElldIi Flare NUT Tube Torque Flare Nut Tightening TorquePR ,LI-1,II Ij iVoltagerange Compressor FAN Electric Heater DataLRA RLA FLA Service Cover Outdoor Unit InstallFan Coil Unit Onto Mounting BracketIndoor and Outdoor Unit START-UP Wireless Remote Controllers --A wireless remoteHeat Microprocessor Control Operation --This sysWill stop30secondsafterthecompressorstopsAfter Emer --Emergency Outdoorair TemperaturefCleaning and Maintenance Schedule To Install or Replace Remote Controller BatteriesTask Monthly Quarterly Yearly Indoor Unit SET Time To Clean Condensate Drains-- Clean all drainsTo Clean Indoor Coil --To clean the coil, remove RemovecoverNO. of Quick System Fault LED Flashes SystemFault CodesMinimum Nominal Maximum Temp Thermistor Ohms Volts -- DC TroubleshootingProblem Potential Source Action 40QN Thermistor PropertiesWall CAP Wireless CONTROLLER*AIRFLOWTo Opendrain RCV Aging CAP CH Comp EMI FMC GNDIFM JEM-A OFM PCB PTCFl I rl Control 38BK009 with 40QNE009 Heat Pump System Wiring Diagram Control PCB A55 Y Page

38AN,BK specifications

The Carrier 38AN,BK is a distinguished model in the world of air conditioning, known for its advanced features, innovative technologies, and exceptional performance. This air conditioning unit is particularly favored for residential and small commercial applications, offering a perfect blend of efficiency, reliability, and comfort.

One of the main features of the Carrier 38AN,BK is its high energy efficiency, which is crucial in today’s eco-conscious environment. With a Seasonal Energy Efficiency Ratio (SEER) rating that often exceeds industry standards, this unit ensures minimal energy consumption while providing powerful cooling capabilities. This not only contributes to lower utility bills but also reduces the overall carbon footprint.

The Carrier 38AN,BK employs advanced cooling technologies that make it a standout choice. One notable feature is its use of a scroll compressor, which operates with fewer moving parts than traditional models, resulting in reduced noise levels and enhanced durability. This compressor design also ensures a smoother operation, translating to consistent temperature control and a more comfortable indoor environment.

Another innovative technology incorporated in the Carrier 38AN,BK is the use of smart controls, allowing users to easily adjust settings and monitor performance through compatible smart devices. This feature adds convenience and flexibility, enabling homeowners to manage their home climate efficiently, even when they are away.

In terms of construction, the Carrier 38AN,BK’s robust design includes a galvanized steel cabinet that is resistant to corrosion and designed to withstand adverse weather conditions. This ensures longevity and reliable performance throughout the year. Additionally, the unit features advanced filtration systems that help improve indoor air quality by reducing allergens and pollutants, further enhancing user comfort.

Furthermore, the Carrier 38AN,BK is designed to operate quietly, making it an ideal choice for bedrooms and other quiet spaces. Its noise reduction features, combined with its energy-saving capabilities, position it as an attractive choice for a wide range of applications.

In summary, the Carrier 38AN,BK air conditioning unit excels in efficiency, advanced technologies, and user-friendly features. Its reliable design and quiet operation make it a top choice for anyone seeking effective and environmentally responsible cooling solutions. As both technology-savvy and eco-friendly, it meets the demands of modern homeowners while delivering exceptional comfort year-round.