Carrier 38AN,BK specifications Lii, High Wall Unit Package Contents

Page 3

m 8 "....._

+

36"

*A clearanceof 31,_"is the absoluteminimumA. clearance of 10"is recommended.

NOTE: Remove unit front cover for control box access.

Fig. 2 --Minimum Required Fan Coil Unit

Clearances

4.Select walls that are:

a.Strong enough to support the weight of the unit (see Tables 4A-4D for unit operating weight).

b.Accessible to convenient condensate drainage.

c.Free of obstacles that may block air circulation to the fan coil.

d.Outside walls (if pussible) to make piping easier.

5.Place top of fan coil unit as high on wall as possible, mak- ing sure that unit is at least 31A in. down from ceiling to

permit proper airflow (the recommended clearance is 10 inches). Also, make sure that the unit is not placed

directly over anything that would prevent filter removal or block airflow.

6.Make sure units are easily accessible to electric power.

7.Refrigerant piping can enter tbe unit through the prepunched holes. Refrigerant piping can run down along the wall, to the right or lef_ along the wall, straight through the wall,

or into the wall (recommended location: right rear). See Fig. 5. Once the piping is through the wall, it can run inside walls, in ceilings, between floors, or straight to the outside. See Fig. 6 for maximum line lengths. See Table 5 for System Piston Guide and Refrigerant Charging.

NOTE: Run refrigerant piping as directly as possible, and avoid any unnecessary turns or bends.

8.Condensate piping can be directed through the inside wall to an approved drain or directed straight outside.

NOTE: The piping hole for condensate line must be made at a downward slope to ensure proper drainage. See Mount Mounting Bracket on Wall section below for details.

Step 3 --Mount Mounting Bracket on Wall

l. Decide how refrigerant will be piped. If necessary, knock out the appropriate pre-puncbed holes (Fig. 5) on unit for piping and electrical connections.

2.Remove bracket from fan coil nnit by pulling it down from fan coil unit bottom as shown in Fig. 7.

3.Using a carpenter's level, fasten mounting brackets into the studs in the wall at least 10 in. away from the ceiling with all the screws provided. Always be sure to insert screws into the top 2 holes indicated in Fig. 7. Make sure the attached bracket will support a 200 lb vertical load. For

a masonry wall, anchor shields can be used to attach bracket to the wall.

4.Temporarily hang unit on bracket to check location and level.

I_] [,,"_lii[.] _I"

If mounting bracket is not mounted level, the indoor sec- tion will be mounted unevenly, and condensate drain- age water may drip onto the floor. Also, a gap between

the bracket and the wall may result in vibration and noise from the indoor section.

5.Mark and cut condensate and piping holes.

a.For piping through the wall, mark the wall below the condensate connection and cut a 2V2-in. hole into the

wall at either point "A" or point "B" in Fig. 8. NOTE: The 2V2-in hole must be made at a downward

slope to ensure proper condensate drainage. See Fig. 9. Slope condensate line at a minimum pitch of 1/4in. per foot of line. The condensate line cannot be run up for upper piping connections -- only refriger- ant lines may be run up.

b.Push the wall sleeve (factory supplied with the unit) through the 2]/2-in. wall opening.

Table 3 --High Wall Unit Package Contents

 

 

 

ITEM

 

QUANTITY

Unit

Mounting

Template

 

1

Unit

Mounting

Bracket

 

1

1-in. Lag Screws for Unit Mounting

 

8

Hollow Wall Anchor Bolls for Unit Mounting

5

Wall Sleeve

with Wall Cap

 

1

Infrared Wireless Remote Control

 

1

AAA Batteries (for Remote Control)

 

2

Remote Control Mounting Bracket

 

1

3/n-in.Lag Screws for Remote Mounting

Bracket

2

35 ff High Voltage Power Wiring

 

 

40QNB009

(3-Wiro with Ground)

 

1

40QNE009 (2-Wire with Ground)

 

1

40QNB012

(2-Wire with Ground)

 

1

40QNH012

(2-Wiro with Ground)

 

1

35 ft High Voltage Control Power Wiring

(3-Wire)

1

35 ft Low Voltage Thermistor Wiring

 

1

Owner's Manual

 

1

Installation

Instructions

 

1

Warranty Registration Card

 

1

Image 3
Contents Service Instructions Heating System Combinations for Indoor Outdoor UnitsSystem Indoor Outdoor Unit CoolingLii High Wall Unit Package ContentsPhysical Data, 40QNB Cooling Only High Wall Units Physical Data, 38AN Cooling Only Condensing UnitsPhysical Data, 38BK009,012 Outdoor Heat Pump Units Unit 38BKRefrigerant Type Operating Weight Physical Data, 40QNEIH Heat Pump High Wall UnitsUnit Ciso,..5s Unit Weightabc 40QN Dimensional DrawingHi--till/I/I System Piston Guide Refrigerant ChargesFig, 6 --Maximum System Line Lengths MAXWall Hole Location For Fan Coil Unit Rear Piping Size 009 Shown?q,ElldIi Flare NUT Tube Torque Flare Nut Tightening TorquePR ,LI-1,II Ij iElectric Heater Data Voltagerange Compressor FANLRA RLA FLA InstallFan Coil Unit Onto Mounting Bracket Service Cover Outdoor UnitIndoor and Outdoor Unit START-UP Wireless Remote Controllers --A wireless remoteHeat Microprocessor Control Operation --This sysWill stop30secondsafterthecompressorstopsAfter Emer --Emergency Outdoorair TemperaturefTo Install or Replace Remote Controller Batteries Cleaning and Maintenance ScheduleTask Monthly Quarterly Yearly Indoor Unit SET Time To Clean Condensate Drains-- Clean all drainsTo Clean Indoor Coil --To clean the coil, remove RemovecoverNO. of Quick System Fault LED Flashes SystemFault CodesMinimum Nominal Maximum Temp Thermistor Ohms Volts -- DC TroubleshootingProblem Potential Source Action 40QN Thermistor PropertiesWireless CONTROLLER*AIRFLOW Wall CAPTo Opendrain RCV Aging CAP CH Comp EMI FMC GNDIFM JEM-A OFM PCB PTCFl I rl Control 38BK009 with 40QNE009 Heat Pump System Wiring Diagram Control PCB A55 Y Page

38AN,BK specifications

The Carrier 38AN,BK is a distinguished model in the world of air conditioning, known for its advanced features, innovative technologies, and exceptional performance. This air conditioning unit is particularly favored for residential and small commercial applications, offering a perfect blend of efficiency, reliability, and comfort.

One of the main features of the Carrier 38AN,BK is its high energy efficiency, which is crucial in today’s eco-conscious environment. With a Seasonal Energy Efficiency Ratio (SEER) rating that often exceeds industry standards, this unit ensures minimal energy consumption while providing powerful cooling capabilities. This not only contributes to lower utility bills but also reduces the overall carbon footprint.

The Carrier 38AN,BK employs advanced cooling technologies that make it a standout choice. One notable feature is its use of a scroll compressor, which operates with fewer moving parts than traditional models, resulting in reduced noise levels and enhanced durability. This compressor design also ensures a smoother operation, translating to consistent temperature control and a more comfortable indoor environment.

Another innovative technology incorporated in the Carrier 38AN,BK is the use of smart controls, allowing users to easily adjust settings and monitor performance through compatible smart devices. This feature adds convenience and flexibility, enabling homeowners to manage their home climate efficiently, even when they are away.

In terms of construction, the Carrier 38AN,BK’s robust design includes a galvanized steel cabinet that is resistant to corrosion and designed to withstand adverse weather conditions. This ensures longevity and reliable performance throughout the year. Additionally, the unit features advanced filtration systems that help improve indoor air quality by reducing allergens and pollutants, further enhancing user comfort.

Furthermore, the Carrier 38AN,BK is designed to operate quietly, making it an ideal choice for bedrooms and other quiet spaces. Its noise reduction features, combined with its energy-saving capabilities, position it as an attractive choice for a wide range of applications.

In summary, the Carrier 38AN,BK air conditioning unit excels in efficiency, advanced technologies, and user-friendly features. Its reliable design and quiet operation make it a top choice for anyone seeking effective and environmentally responsible cooling solutions. As both technology-savvy and eco-friendly, it meets the demands of modern homeowners while delivering exceptional comfort year-round.