Grizzly H7947, H7948 instruction manual Troubleshooting, Symptom Possible Cause Solution

Page 20

TROUBLESHOOTING

Symptom

Possible Cause

Solution

Air leaking at trig-

1.

O-rings in trigger valve hous-

1.

O-rings must be replaced.

ger valve area.

 

ing are damaged.

 

 

 

 

 

 

 

Air leaking between

1.

Loose screws in housing.

1.

Tighten screws.

housing and hose.

2.

Damaged O-ring.

2.

Replace O-ring.

 

3.

Loose air fitting.

3.

Tighten air fitting & use

 

 

 

 

Teflon tape.

 

 

 

 

 

Air leaking between

1.

Damaged cap gasket.

1.

Replace gasket.

housing and cap

 

 

 

 

assembly.

 

 

 

 

 

 

 

 

 

Tool skips staples

1.

Air leaks.

1.

Tighten screws and fittings.

while discharging.

2.

Dirt in nose.

2.

Clean nose.

 

3.

Dirt or damage prevents stap-

3.

Clean magazine, inspect/

 

 

less from moving freely in

 

repair damage; insert a

 

 

magazine.

 

clean strip of staples.

 

4.

Inadequate air flow to tool.

4.

Check fitting, hose, com-

 

 

 

 

pressor & air pressure.

 

5.

Worn O-ring on piston or lack

5.

Replace piston O-ring.

 

 

of lubrication.

 

Lubricate.

 

6.

Damaged O-rings on trigger

6.

Replace trigger valve O-

 

 

valve.

 

rings.

 

7.

Worn bumper.

7.

Replace bumper.

 

 

 

 

 

Tool runs slowly

1.

Stapler is not sufficiently lubri-

1.

Lubricate stapler.

or has a loss of

 

cated.

 

 

power.

2.

Compressor is not supplying

2.

Repair or replace compres-

 

 

at least 70 PSI of air pressure

 

sor.

 

 

to the tool.

 

 

 

3.

Exhaust port in cap is blocked.

3.

Clean or replace damaged

 

 

 

 

internal parts.

 

 

 

 

 

Staples frequently

1.

Staples are the wrong size.

1.

Use correct staples.

jam in the stapler

2.

Staples are bent or dirty.

2.

Use undamaged, clean

nose.

 

 

 

staples.

 

3.

Magazine or nose screws are

3.

Tighten magazine.

 

 

loose.

 

 

 

4.

Driver or driver guide are worn

4.

Replace worn or damaged

 

 

or damaged.

 

parts.

 

 

 

 

 

Stapler does not

1.

Staple is jammed in magazine

1.

Clear stapler magazine or

fire.

 

or discharge area.

 

discharge area.

 

2.

Piston shaft is damaged.

2.

Replace piston shaft.

 

3.

Air pressure too low.

3.

Check/increase air pres-

 

 

 

 

sure.

 

 

 

 

 

-18-

H7947/H7948 16 Gauge Stapler

Image 20
Contents Model H7947/H7948 Safety Safety Instructions For Pneumatic ToolsBefore Operating This Equipment Mation about proper operation of the equipmentAlways Wear Ansi Approved Hearing Protection Additional Safety Instructions for Staplers H7947/H7948 16 Gauge Stapler Foreword Model H7948 Specifications Model H7947 SpecificationsIntroduction Contact InfoModel H7947/H7948 Figure SetupUnpackingInventory Compressed Air System Testing Safety Nose Mechanism To verify that the safety nose is working correctlyOperations Loading StaplesUnloading Staples To load staples in your staplerUsing the Stapler To operate your staplerAdjusting Depth To adjust the depthClearing Jammed Staples To clear a jammed staple from the dis- charge areaReplacing Pistons/O-Rings To replace a piston and O-ringsCleaning & Lubricating CleaningLubricatingH7947 Parts Breakdown H7947 Parts List DescriptionH7948 Parts Breakdown H7948 Parts List Troubleshooting Symptom Possible Cause SolutionWarranty and Returns Page Warranty Card Name Street CityStateZip BOX BELLINGHAM, WA