12Volt 12V6CF owner manual Finding a location

Page 7

Finding a location

In finding a location for your compressor...

1.Find a location in which the 12-Voltair can get adequate ventilation.

2.Find a location in which the 12-Voltair will not be overly exposed to dirt and dust.

3.Find a location in which the 12-Voltair can be properly fastened to ensure that it does not shift.

4.Check the underside to make sure that any drilling of holes will not interfere with existing lines or structure.

Once you have decided on a location for the 12-Voltair...

1) Set the unit into position

Mounting Holes

 

2) Mark the 3 holes on the right side of the compressor base

Ground Wire

onto the floor of your location.

Air Line

3) Mark the 4 mounting holes of the base of the 12-Voltair on

Positive Wire

 

the floor of your location

 

4) Set the unit aside and get ready to drill some holes

 

CAUTION:

Use good common sense when installing the 12-Voltair. When drilling holes for mounting,

Electrical and plumbing, be sure to check the underside to make sure your drill will not interfere

or damage existing lines, hoses or structure.

HOW BIG OF A HOLE SHOULD I DRILL? To eliminate any potential problems, Voltair recommends adding extra protection around the wires and hose (such as running the wires and hose through another hose, or use a rubber grommet). However you decide, drill a hole at least 1/8” bigger than the outside diameter of the hose/wires that will be run through the floor of your location.

5)Drill your holes

-3/8” hole for 5/16” x 1 1/2” mounting bolts

-holes for electrical and plumbing

6)Once your holes are drilled, move the 12-Voltair back into position and use the provided 5/16” x 1 1/2” bolts, lock washer and nut to secure it to the floor. If possible also drill through the side of the

12-Voltair cabinet to secure it at a higher point.

a)Deck Mount- use all 4 mounting holes in base of the 12- Voltair frame.

b)Bed Side Mount- use at least 2 of the for mounting holes on the base of the 12-Voltair as well as 2 holes higher up on the back of cabinet as shown in the above diagram.

Here is an example of

protecting wires by either using ‘another hose’ or ‘rubber grommet.’

Here is an example of securing the cabinet ‘at a

higher point’ for a bed side mount

Once the 12-Voltair is securely fastened to the vehicle go to next page.

“Air Where And When You Need It!”

®

 

Page 

Image 7
Contents Questions? Warranty Table of Contents Important safety precautions Before you begin Side Latches AssemblyQuick Coupler Finding a location Positive Wire Ground WireElectrica l Your switch should be ready to go Circuit Breaker Toggle SwitchElectrica l optio nal Time It Take To Fill Air Storage Tank Gallon 150 PSI Plumbing125-150 PSI Maintenance VDC Power Source WiringMy 12-Voltair not run TroubleshootingMy 12-voltair just starts stops starts stops How do I adjust my pressure switchMy 12-Voltair shakes a lot My 12-Voltair runs but is not able to pump up any pressureModel # 12V6CF Serial # Warr ant yAir Where And When You Need It