Mode Switching Summary
TEST
AUTO
Flip light switch off for
MANUAL MODE one second then back on*
*If you get confused while switching modes, turn the power off for one minute, then back on. After thecalibrationtimethecontrolwillbeintheAUTO mode.
Adjustment of Coverage Area
The sensor on this light fixture detects “motion” by the movement of heat across the coverage area. However, following are examples of objects that also produce heat and can cause the sensor to trigger:
• Pools of Water | • Air Conditioners |
• Dryer Vents | • Animals |
• Heating Vents | • Automobile Traffic |
If you suspect that a heat source of this type is triggering the sensor, reduce the sensitivity.
Range | SPECIFICATIONS |
Up to 30 ft. (9.1 m) [varies with surrounding temperature]. | |
Sensing Angle | Up to 150°, 240° adjustable |
Electrical Load | Up to 100 Watt Maximum Incandescent |
Bulb Type | Medium Base, Type “A”, 100 Watt Maximum |
Sensor Capacity | Up to 500 Watt (4.1 A) Maximum |
Power Requirements | 120 VAC, 60 Hz |
Operating Modes | TEST, AUTO, and MANUAL MODE |
1, 5, 10 minutes | |
Test Timer | 5 Seconds |
Manual Mode Timer |