| CLEANGUARD WET LOCATION WES SERIES 2X2 |
Page 2 of 2 | 2' x 2' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE |
| 2 LAMP, T8 OR T12 |
PHOTOMETRY
MODEL NO. WES2GFSVA26U |
| LER = FL - 58.6 | IW - 56.3 | BF - 0.87 |
|
|
|
|
| |||||||||
| Comparative yearly lighting energy cost per 1000 lumens = $4.00 | |||||||||||||||||
|
| coefficients of utilization — zonal cavity method | (effective floor cavity reflectance 0.20) |
| ||||||||||||||
|
|
| ||||||||||||||||
|
|
| RF |
|
| 20 |
|
|
|
|
| 20 |
|
|
|
| 20 |
|
|
|
| RC |
|
| 80 |
|
|
|
|
| 50 |
|
|
|
| 30 |
|
|
|
| RW | 70 |
| 50 |
|
| 30 |
| 50 | 30 |
| 10 |
| 50 | 30 | 10 |
|
|
| 1 | 79 |
| 75 |
|
| 73 |
| 71 | 69 |
| 67 |
| 68 | 66 | 65 |
|
| ratio | 2 | 72 |
| 67 |
|
| 62 |
| 63 | 59 |
| 56 |
| 61 | 58 | 55 |
|
| 3 | 66 |
| 59 |
|
| 54 |
| 56 | 52 |
| 48 |
| 54 | 51 | 47 | |
|
| cavity | 4 | 61 |
| 53 |
|
| 47 |
| 50 | 46 |
| 42 |
| 49 | 45 | 41 |
|
| 5 | 56 |
| 48 |
|
| 42 |
| 45 | 40 |
| 37 |
| 44 | 40 | 36 | |
|
| room | 6 | 52 |
| 43 |
|
| 37 |
| 41 | 36 |
| 32 |
| 40 | 36 | 32 |
|
| 7 | 49 |
| 39 |
|
| 33 |
| 38 | 33 |
| 29 |
| 37 | 32 | 29 | |
|
|
|
|
|
|
|
|
| ||||||||||
|
|
| 8 | 45 |
| 36 |
|
| 30 |
| 35 | 30 |
| 26 |
| 34 | 29 | 26 |
|
|
| 9 | 42 |
| 33 |
|
| 28 |
| 32 | 27 |
| 24 |
| 31 | 27 | 23 |
|
|
| 10 | 40 |
| 31 |
|
| 25 |
| 30 | 25 |
| 21 |
| 29 | 25 | 21 |
|
| visual comfort probability | (rated lumens per lamp 3150.) |
|
|
|
|
| ||||||||||
|
|
| room size |
|
|
| ceiling height |
|
|
|
|
| ceiling height |
| ||||
|
| W |
| L |
|
| 8.5 | 10.0 | 13.0 | 16.0 |
|
|
| 8.5 | 10.0 | 13.0 | 16.0 | |
| 20 |
| 20 |
|
|
| 56 | 60 | 66 | 73 |
|
|
| 53 | 57 | 63 | 70 | |
| 20 |
| 30 |
|
|
| 50 | 53 | 57 | 63 |
|
|
| 46 | 50 | 54 | 60 | |
| 20 |
| 40 |
|
|
| 47 | 49 | 53 | 57 |
|
|
| 42 | 45 | 49 | 53 | |
|
| 20 |
| 60 |
|
|
| 43 | 46 | 49 | 52 |
|
|
| 38 | 41 | 44 | 48 |
| 30 |
| 20 |
|
|
| 58 | 61 | 66 | 72 |
|
|
| 56 | 60 | 63 | 69 | |
| 30 |
| 30 |
|
|
| 51 | 54 | 57 | 62 |
|
|
| 48 | 51 | 54 | 59 | |
| 30 |
| 40 |
|
|
| 47 | 49 | 52 | 55 |
|
|
| 43 | 46 | 49 | 52 | |
| 30 |
| 60 |
|
|
| 43 | 46 | 47 | 50 |
|
|
| 38 | 41 | 43 | 47 | |
|
| 30 |
| 80 |
| lengthwise |
| 42 | 44 | 45 | 48 |
|
| crosswise | 36 | 39 | 40 | 44 |
| 40 |
| 40 |
|
| 48 | 50 | 52 | 55 |
|
| 44 | 47 | 50 | 53 | |||
| 40 |
| 20 |
|
|
| 59 | 63 | 67 | 71 |
|
|
| 58 | 62 | 65 | 70 | |
| 40 |
| 30 |
|
|
| 52 | 55 | 58 | 62 |
|
|
| 50 | 53 | 56 | 60 | |
| 40 |
| 60 |
| luminaries |
| 44 | 46 | 48 | 50 |
|
| luminaries | 39 | 42 | 44 | 47 | |
| 40 |
| 80 |
|
| 42 | 44 | 44 | 47 |
|
| 37 | 39 | 40 | 43 | |||
|
| 40 |
| 100 |
|
|
| 42 | 43 | 43 | 45 |
|
|
| 36 | 38 | 38 | 41 |
| 60 |
| 30 |
|
|
| 53 | 56 | 59 | 63 |
|
|
| 51 | 55 | 57 | 61 | |
| 60 |
| 40 |
|
|
| 48 | 51 | 53 | 56 |
|
|
| 46 | 49 | 51 | 54 | |
| 60 |
| 60 |
|
|
| 44 | 47 | 48 | 50 |
|
|
| 40 | 43 | 44 | 48 | |
|
|
|
|
|
|
| ||||||||||||
| 60 |
| 80 |
|
|
| 42 | 44 | 44 | 47 |
|
|
| 38 | 40 | 40 | 43 | |
|
| 60 |
| 100 |
|
|
| 42 | 43 | 42 | 45 |
|
|
| 37 | 38 | 38 | 41 |
| 100 |
| 40 |
|
|
| 51 | 53 | 55 | 58 |
|
|
| 49 | 52 | 54 | 57 | |
| 100 |
| 60 |
|
|
| 47 | 49 | 49 | 52 |
|
|
| 44 | 46 | 47 | 50 | |
| 100 |
| 80 |
|
|
| 44 | 46 | 46 | 48 |
|
|
| 41 | 42 | 43 | 46 | |
|
| 100 |
| 100 |
|
|
| 43 | 44 | 43 | 46 |
|
|
| 39 | 40 | 40 | 41 |
ORDERING INFORMATION
Explanation of Catalog Number. Example: WES2GFSVA26U120SOGLR
WE
CLEANGUARD
WET
LOCATION
S
STATIC
2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FIXTURE |
|
|
|
| LENS FRAME: |
|
| LAMP QUANTITY: |
|
| ||||||||
WIDTH |
|
|
| FS= Flat steel frame |
|
| 2=2 Lamp |
|
|
|
|
| ||||||
|
|
|
|
|
| RA=Regressed |
|
| 3=3 Lamp |
|
|
|
|
| ||||
|
|
|
|
|
|
| aluminum frame |
|
| (Not with 6" spacing) |
|
| ||||||
|
|
|
|
|
| FA=Flat aluminum frame |
| 4=4 Lamp |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| (T8, 2' Lamp Only) |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LAMP/ | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| FIXTURE LENGTH: | ||||
|
|
|
| CEILING | TYPE: |
|
| LENS/SHIELDING TYPE: | 6U=6"U Lamp T8 or T12 | |||||||||
|
| G= Grid |
|
|
| VA (virgin acrylic) | 2U=T8, | |||||||||||
|
| F=Flanged (overlap) Z spline |
|
| standard (see options and | FT=Twin Tube T5 | ||||||||||||
|
|
| and plaster frame |
|
|
| consult factory) | 17=T8, 2' Lamp | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| (Nominal 24") | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VOLTAGE: |
|
|
|
| OPTIONS: | ||||
|
|
| Add appropriate suffix to | ||||||
120 or 277 |
|
|
| ||||||
|
|
| catalog no., ie: (GLR) | ||||||
|
|
|
|
|
| ||||
|
|
|
|
| |||||
|
|
| BALLAST TYPE: |
|
|
| |||
LE | <10THD | ||||||||
|
|
|
|
| <20THD | ||||
1 & 2 Lamp Elec. T8 | SO* | HI* | |||||||
Lamp Elec. T8 | SO* | HI* | |||||||
Lamp Elec. TT5 | SB* | IB* | |||||||
| (40 Watt) | X3* | I3* | ||||||
Lamp Elec. TT5 | |||||||||
Lamp Elec. T8 | O4* | H4* | |||||||
LOL Dimming (T8) | PS | – | |||||||
LOL Dimming (TT5) | PB | – |
Other dimming options. Consult factory.
*Instant Start Standard
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12 with 6.8 oz. average weight per square foot.
PLASTER FRAME: Catalog number: PF22.
CONTINUOUS ROW INSTALLATION: For F type fixtures,
are required between fixtures. Order Catalog Number: S2FC TRIM (each joint). RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.
FUSING: Internal
ELECTRICAL/WIRING OPTIONS: Consult factory.
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio
CHICAGO PLENUM: SUFFIX: CP.
MATERIALS: Chassis parts are
FINISH: Chassis
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall be not less than 40 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2629 candelas per square meter. To control veiling reflections, luminaire output in the
Job Information |
| Type: |
Lightolier a Genlyte Thomas Company | www.lightolier.com |
Technical Information: (978)
631 Airport Road, Fall River, MA 02720 • (508)
© 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902