Goldstar M5203L Specifications, Safety Precautions, Insulation Resistance Test, Models, M5203R

Models: LWC061JGMK1 LWJ0611PCG M5203L M5203R M6003R M5403R WM-6011

1 32
Download 32 pages 48.83 Kb
Page 3
Image 3
1.2 SPECIFICATIONS

1.2 SPECIFICATIONS

MODELS

M5403R

 

M5203R

 

M5203L

M6003R

LWJ0611PCG

ITEMS

 

 

WM-6011

LWC061JGMK1

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING CAPACITY (BTU/h)

5,300

 

5,200

 

5,200

6,000

6,000

 

 

 

 

 

 

 

 

POWER SUPPLY (Phase, V, Hz)

 

 

 

 

1ø, 115V, 60HZ

 

 

 

 

 

 

 

 

 

 

INPUT (W)

 

530

 

470

610

620

 

 

 

 

 

 

 

 

OPERATING CURRENT (AMP.)

 

4.8

 

4.3

5.6

5.8

 

 

 

 

 

 

 

 

REFRIGERANT CONTROL

 

 

 

CAPILLARY TUBE

 

 

 

 

 

 

 

 

REFRIGERANT CHARGE (R-22)

230g (8.1 Oz )

 

330g(11.6 Oz)

335g (11.8 Oz)

235g (8.3 Oz)

 

 

 

 

 

 

 

 

INSIDE FAN

 

 

 

TURBO

 

 

 

 

 

 

 

 

 

OUTSIDE FAN

 

 

PROPELLER FAN WITH SLINGER RING

 

 

 

 

 

 

 

 

AIR DISCHARGE

 

 

2-WAY (RIGHT AND LEFT)

 

 

 

 

 

 

 

 

CHASSIS

 

 

TOP-DOWN

 

 

 

 

 

 

 

 

PROTECTOR

• OVERLOAD PROTECTOR FOR COMPRESSOR

 

• INTERNAL PROTECTOR FOR FAN MOTOR

 

 

 

 

 

 

 

 

 

 

TEMPERATURE CONTROL

 

 

THERMISTOR

 

 

 

 

 

 

 

 

ROTARY SWITCH

5 POSITIONS (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL)

 

 

 

 

 

 

 

FAN MOTOR

6 POLES, 16W

 

6 POLES, 21.3W

6 POLES, 24W

6 POLES, 21.4W

 

 

 

 

 

 

 

 

NOTE: Specifications are subject to minor change without notice for further improvement.

1.3 SAFETY PRECAUTIONS

1.When servicing, set the POWER of CONTROL BOARD to Off and unplug the power cord.

2.Observe the original lead dress.

If a short circuit is found, replace all parts which have been overheated or damaged by the short cir- cuit.

3.After servicing, make an insulation resistance test to prevent the customer's exposure to shock hazards.

1.4 INSULATION RESISTANCE TEST

1.Unplug the power cord and connect a jumper between 2 pins (black and white).

2.The grounding conductor (green or green and yel- low) is to be open.

3.Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment at all Mode [except POWER OFF].

4.The value should be over 1 M.

—3—

Page 3
Image 3
Goldstar M5203L, WM-6011 Specifications, Safety Precautions, Insulation Resistance Test, Models, M5203R, M6003R, Items