Goldstar M5203L, WM-6011, M6003R, M5403R, M5203R, LWC061JGMK1, LWJ0611PCG service manual Piping System

Models: LWC061JGMK1 LWJ0611PCG M5203L M5203R M6003R M5403R WM-6011

1 32
Download 32 pages 48.83 Kb
Page 17
Image 17
4.2 PIPING SYSTEM

4.2 PIPING SYSTEM

CAPILLARY

TUBE

CONDENSER COILS

FAN

MOTOR

TURBO FAN

EVAPORATOR COILS

Following is a brief description of the important components and their function in what is called the refrigeration system. Reference should be made to Figure 32 to follow the refrigerating cycle and the flow of the refrigerant in the cooling cycle.

ROOM AIR CONDITIONER

CYCLE OF REFRIGERATION

EVAPORATOR COILS

CONDENSER COILS

COOLED

AIR

LIQUID

PRESSURE

DROP

 

SUCTION LINE

VAPOR INLET

HOT

COMPLETE LIQUID

 

COOL LOW PRESSURE VAPOR

BOIL OFF POINT

DISCHARGED

 

 

 

 

 

AIR

ROOM AIR HEAT LOAD

 

 

 

 

 

OUTSIDE COOLING

 

 

 

AIR FOR REFRIGERANT

 

 

 

PASS THROUGH

 

MOTOR

 

 

DISCHARGE

 

LINE

COMPRESSOR

NOT HIGH PRESSURE

VAPOR

OIL

 

 

LIQUID OUTLET

(LIQUID REFRIGERANT)

 

 

HIGH PRESSURE VAPOR

CAPILLARY TUBE

LIQUID REFRIGERANT

 

LOW PRESSURE VAPOR

Figure 32

— 17—

Page 17
Image 17
Goldstar M5203L, WM-6011, M6003R, M5403R, M5203R, LWC061JGMK1, LWJ0611PCG service manual Piping System