HIGH ELEVATIONS

CDVSC7 & CDV7 Series Gas Fireplace product features & Gas specifications

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having juris- diction.

In Canada, please consult provincial and/or local authori- ties having jurisdiction for installations at elevations above 4,500 feet (1,370 m).

GAS pressures

 

Natural

Propane (LP)

Inlet Minimum

5.5” w.c.

11.0” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

GAS SPECIFICATIONS & ORIFICE SIZE CDVR SERIES

 

 

Max.Input

Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

CDVR33NV7

Nat.

18,000

13,000

#45

CDVR33PV7

LP

18,000

13,000

1.28 mm

CDVR33NE7

Nat.

18,000

13,000

#45

CDVR33PE7

LP

18,000

13,000

1.28 mm

CDVR33NSC7

Nat.

18,000

13,000

#45

CDVR33PSC7

LP

17,000

14,000

1.25 mm

CDVR36NV7

Nat.

20,000

15,000

#44

CDVR36PV7

LP

20,000

15,000

1.35 mm

CDVR36NE7

Nat.

20,000

15,000

#44

CDVR36PE7

LP

20,000

15,000

1.35 mm

CDVR36NSC7

Nat.

20,000

15,000

#44

CDVR36PSC7

LP

20,000

15,000

1.35 mm

CDVR42NV7

Nat.

24,000

17,000

2.35 mm

CDVR42PV7

LP

24,000

18,000

1.45 mm

CDVR42NE7

Nat.

24,000

17,000

2.35 mm

CDVR42PE7

LP

24,000

18,000

1.45 mm

CDVR42NSC7

Nat.

24,000

17,000

2.35 mm

CDVR42PSC7

LP

24,000

18,000

1.45 mm

CDVR47NV7

Nat.

24,000

17,000

2.35 mm

CDVR47PV7

LP

24,000

18,000

1.45 mm

CDVR47NE7

Nat.

24,000

17,000

2.35 mm

CDVR47PE7

LP

24,000

18,000

1.45 mm

CDVR47NSC7

Nat.

24,000

17,000

2.35 mm

CDVR47PSC7

LP

24,000

18,000

1.45 mm

 

 

 

 

 

GAS SPECIFICATIONS & ORIFICE SIZE CDVT SERIES

 

 

Max.Input

Min. Input

Orifice

Model

Fuel

BTU/h

BTU/h

Size

CDVT33NV7

Nat.

18,000

13,000

#45

CDVT33PV7

LP

18,000

13,000

1.28 mm

CDVT33NE7

Nat.

18,000

13,000

#45

CDVT33PE7

LP

18,000

13,000

1.28 mm

CDVT33NSC7

Nat.

18,000

13,000

#45

CDVT33PSC7

LP

18,000

13,000

1.28 mm

CDVT36NV7

Nat.

20,000

15,000

#44

CDVT36PV7

LP

20,000

15,000

1.35 mm

CDVT36NE7

Nat.

20,000

15,000

#44

CDVT36PE7

LP

20,000

15,000

1.35 mm

CDVT36NSC7

Nat.

20,000

15,000

#44

CDVT36PSC7

LP

20,000

15,000

1.35 mm

CDVT42NV7

Nat.

24,000

17,000

2.35 mm

CDVT42PV7

LP

24,000

18,000

1.45 mm

CDVT42NE7

Nat.

24,000

17,000

2.35 mm

CDVT42PE7

LP

24,000

18,000

1.45 mm

CDVT42NSC7

Nat.

24,000

17,000

2.35 mm

CDVT42PSC7

LP

24,000

18,000

1.45 mm

CDVT47NV7

Nat.

24,000

17,000

2.35 mm

CDVT47PV7

LP

24,000

18,000

1.45 mm

CDVT47NE7

Nat.

24,000

17,000

2.35 mm

CDVT47PE7

LP

24,000

18,000

1.45 mm

CDVT47NSC7

Nat.

24,000

17,000

2.35 mm

CDVT47PSC7

LP

24,000

18,000

1.45 mm

 

 

 

 

 

69D3011