CDVSC7 & CDV7 Series Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND

OPERATing INSTRUCTIONS

1.STOP! Read the safety information above.

2.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

3.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 41. If you do not smell gas, go to next step.

4.Press the master switch to the "ON" (-) position. Within eight (8) seconds it will beep once. This indi- cates the system is ready.

5.Press "ON " button. Sparker will spark and pilot flame will light.

6.Once pilot flame is established, the main burner flame will light automatically.

7.If the pilot will not stay lit after several tries, turn the master switch to "OFF" and call your service technician or gas supplier.

 

OFF

Master

 

 

Switch

OFF

ON

ON

 

 

Command Center

TO TURN OFF GAS TO APPLIANCE

1.Turn master switch to "OFF".

2.Turn off all electrical power to the appliance if service is to be performed.

42

69D3011

Page 42
Image 42
Monessen Hearth CDV7 manual OPERATing Instructions, Command Center