CDVSC7 & CDV7 Series Gas Fireplace

Millivolt OPERATING INSTRUCTIONS

for your safety read before lighting

WARNING

If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the appliance.

Open windows.

Do not attempt to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instruc- tions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.

Lighting pilot for the first time

initial lighting

Purge air from the supply line as follows:

Open main shutoff valve.

Unscrew main pressure test point.

Leave inlet test screw open until gas comes in.

When gas is flowing, tighten inlet screw immedi- ately.

WARNING

Never use an open flame to check for gas leak.

leak testing

1.Follow the pipe from the gas supply line connection to the gas valve. Check connection for leaks with soap and water mixture.

2.Next check for gas leaks at the burner with soap and water mixture.

3.Check the pilot for gas leaks with soap and water mixture.

32

69D3011

Page 32
Image 32
Monessen Hearth CDV7 manual Millivolt Operating Instructions, Initial lighting, Leak testing