CDVSC7 & CDV7 Series Gas Fireplace |
Before You Start
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:
•Fireplace (Firebox and Burner System)
•Log Set
•Volcanic Rock
•Rock Wool
Items Required For Installation
Tools: | Building Supplies: | ||
• | Phillips Screwdriver | • | Framing Materials |
• | Hammer | • | Wall Finishing Materials |
• Saw and/or saber saw | • | Level | |
• Electric Drill and Bits | • | Tee Joint | |
• | Pliers | • | Measuring Tape |
• | Square | • | Pipe Wrench |
•Caulking Material (Noncombustible)
•Fireplace Surround Material (Noncombustible)
•Piping Complying with Local Codes
•Pipe Sealant Approved for use with Propane/LPG (Resistant to Sulfur Compounds)
firebox framing FOR CDVR
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 for your specific installation requirements. Refer to Figure 2 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs. NOTE: CDVR33SC7 does not have standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure.
firebox framing FOR CDVT
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 3 for your specific installation requirements. Refer to Figure 3 for firebox dimensions. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure.
WARNING
Do not fill spaces around firebox with insulation or other materials. This could cause a fire.
NOTE
COLD CLIMATE INSULATION
If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above ground level.
69D3011