CDVSC7 & CDV7 Series Gas Fireplace

OPTIONAL FAN BLOWER SYSTEMS

BLOT AUTOMATIC THERMOSTAT BLOWER

Receptacle

Junction

Box

120VAC

BLACK

GREEN

WHITE BLACK

WHITE BLACK

BLACK

FP2675

 

Speed Control

Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with prevailing codes.

Figure 58 -

BLOT Blower Wiring Diagram

FK-12 MANUAL BLOWER

1.This must be done before framing the fireplace. When installing the FK-12 blower, a wall switch control must be installed to control the blower.

2.The fireplace power supply is wired through the blower wall switch and then brought to the fireplace junction box.

3.The jumper clip on the plug receptacle must be re- moved. Figure 59. Use needlenose pliers to break off the jumper clip.

Plug into switch outlet

Jumper clip on plug

 

 

receptacle must be

 

Blower

removed on power side to

 

Wall Switch

make outlet switchable

 

 

 

Junction Box

Red

 

 

Black

Black (live)

 

 

Green (ground)

 

 

White (neutral)

 

 

FP2676

Figure 59 -

FK-12 Blower

FK-12 Blower wiring Diagram

 

40

69D3011

Page 40