Do not use open flame to check for gas

CHECK GAS PRESSURE & Electrical installation CDVSC7 & CDV7 Series Gas Fireplace

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the

appliance. Contact your dealer immediately.

2. To ease installation, a 30" (mm) flex line with manual shut- off valve has been provided with this appliance. Install and attach 1/2" gas line onto shut-off valve.

3. After completing gas line connection, purge air from

 

 

gas line and test all gas joints from the gas meter

 

 

to the fireplace for leaks. Use a solution of 50/50

Pressure

 

water and soap or a gas sniffer.

 

Test “IN”

 

4. To adjust flame height, turn HI/LO knob to HI to get

 

 

 

maximum pressure to burner. Turn HI/LO knob to

Pressure

FP1979

LO to get minimum pressure.

Test “OUT”

 

5. To check gas pressures at valve, turn captured

HI/LO Knob

 

screw counter clockwise 2 or 3 turns and then place

 

tubing to pressure gauge over test point. Turn unit

Pilot Adjustment Screw

to high. Figure 42. After taking pressure reading,

 

Figure 42 -

be sure and turn captured screw clockwise firmly

 

Gas Pressure Check at Gas Valve

to reseal. Do not over torque. Check test points for

 

 

gas leaks.

WARNING

 

 

Do not use open flame to check for gas

 

 

leaks.

Electrical Wiring

This fireplace will work without any electrical supply. Electricity is only needed to operate blower.

NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when

 

 

servicing controls. Wiring errors can cause

 

improper and dangerous operation.

 

 

 

Verify proper operation after servicing.

69D3011

29

Page 29
Image 29