Ducane (HVAC) 2HP13 Important System Information, Regular Maintenance Requirements, Air Filter

Page 16

On models without a fan Selection Switch, the fan will cycle with the outdoor unit.

Important System Information

!Your system should never be operated without a clean air filter properly installed.

!Return air and supply air registers should be free from restrictions or obstructions to allow full flow of air.

Regular Maintenance Requirements

Your system should be regularly inspected by a qualified service technician. These regular visits may include (among other things) checks for:

!Motor operation

!Ductwork air leaks

!Coil & drainpan cleanliness (indoor & outdoor)

!Electrical component operation & wiring check

!Proper refrigerant level & refrigerant leaks

!Proper airflow

!Drainage of condensate

!Air filter(s) performance

!Blower wheel alignment, balance & cleaning

!Primary & secondary drain line cleanliness

!Proper defrost operation (heat pumps)

There is some routine maintenance procedures you can do to help keep your system operating at peak performance between visits.

Air Filter

Inspect air filters at least monthly and replace or clean as required. Disposable filters should be replaced. Washable filters may be cleaned by soaking in mild detergent and rinsing with cold water. Replace filters with the arrows pointing in the direction of airflow. Dirty filters are the most common cause of poor heating / cooling performance and compressor failures.

Indoor Coil

If the system has been operated with a clean filter in place, it should require minimal cleaning. Use a vacuum cleaner and soft brush attachment to remove any accumulation of dust from the top and underside of the finned coil surface. However, perform this maintenance only when the coil is completely dry.

If the coil cannot be cleaned by this method, call your dealer for service. It may need a detergent solution and rinsing with water for cleaning, which may require coil removal. You should not attempt this yourself.

Condensate Drain

During cooling season check at least monthly for free flow of drainage and clean if necessary.

Condenser Coils

Grass cuttings, leaves, dirt, dust, lint from clothes dryers, and fall off from trees can be drawn into coils by movement of the air. Clogged condenser coils will lower the efficiency

of your unit and could cause damage to the condenser. Periodically, debris should be brushed from the condenser coils.

. . . . .

SHARP OBJECT HAZARD!

Condenser coils have sharp edges. Wear adequate body protection on body extremities (e.g. gloves).

FAILURE TO FOLLOW THIS WARNING COULD RESULT IN BODILY INJURY.

Use a soft bristle brush with light pressure only. DO NOT damage or bend condenser coil fins. Damaged or bent fins may affect unit operation.

Painted Surfaces

For maximum protection of the unit's finish, a good grade of automobile wax should be applied every year. In geographical areas where water has a high concentration of minerals (calcium, iron, sulfur, etc.). It is recommended that lawn sprinklers not be allowed to spray the unit. In such applications, the sprinklers should be directed away from the unit. Failure to follow this precaution may result in premature deterioration of the unit finish and metal components.

In sea coast areas, special maintenance is required due to the corrosive atmosphere provided by the high salt concentration in ocean mists and the air. Periodic washing of all exposed surfaces and coil will add additional life to your unit. Please consult your installing dealer for proper procedures in your geographic area.

IF YOUR SYSTEM DOES NOT WORK, BEFORE REQUESTING A SERVICE CALL:

1.Ensure thermostat is set below (cooling) or above (heating) room temperature and that the system lever is in the "COOL", "HEAT" or "AUTO" position.

2.Inspect your return air filter: If it is dirty your air conditioner may not function properly.

3.Check indoor and outdoor disconnect switches. Confirm circuit breakers are ON or that fuses have not blown. Reset breakers/replace fuses as necessary.

4.Inspect the outdoor unit for clogged condenser coils, (grass cuttings, leaves, dirt, dust or lint). Ensure that branches, twigs or other debris are not obstructing the condenser fan.

IF YOUR SYSTEM STILL DOES NOT OPERATE, CONTACT YOU SERVICING DEALER.

Be sure to describe the problem, and have the model and serial numbers of the equipment available.

If warranted replacements parts are required, the warranty must be processed through a qualified distribution location.

100402-07

Issue 0733

Page 16 of 18

Image 16
Contents Table of Contents Install on a Solid, Level Mounting Pad Unit Location & InstallationOutdoor Section Do Locate the Unit Do not Locate the UnitInstallation of Line Sets Recommended Liquid & Vapor Tube DiametersLeak Check Evacuating And Charging InstructionsOpening Service Valves Install Electrical AccessoriesControl Wiring Electrical ConnectionsStart-Up Procedure Adjusting ChargeRefrigeration Charge Adjustment Emergency Heat heating heat pumpSystem Operation Time Delay Pressure Switch CircuitDiagnostic Leds Defrost Control board Diagnostic LEDSingle Phase Wiring Diagram 3 Phase Wiring Diagram Required Superheat for 2HP13 B,L18P-1A Heating Mode Pressures 2HP13B,L24P-1ARequired Superheat for 2HP13 B,L24P-1A Heating Mode Pressures 2HP13B,L30P-1A Heating Mode Pressures 2HP13B,L36P-1ARequired Superheat for 2HP13 B,L30P-1A Required Superheat for 2HP13 B,L36P-1AHeating Mode Pressures 2HP13B,L42P-1A Heating Mode Pressures 2HP13B,L48P-1ARequired Superheat for 2HP13 B,L42P-1A Required Superheat for 2HP13 B,L48P-1AHeating Mode Pressures 2HP13B,L60P-1A Required Superheat for 2HP13 B,L60P-1ACase of extended power outage Temperature Setting LeversFan Switch System SwitchRegular Maintenance Requirements Important System InformationAir Filter Indoor CoilThese Warranties Apply only Company will not be Responsible forIssue

2HP13 specifications

Ducane, a well-respected name in the HVAC industry, offers a range of innovative heating, ventilation, and air conditioning solutions. One standout model in their lineup is the Ducane 2HP13, a 13 SEER central air conditioning unit that combines efficiency, reliability, and advanced technology to create comfortable indoor climates.

One of the main features of the Ducane 2HP13 is its efficient 13 SEER rating, which stands for Seasonal Energy Efficiency Ratio. This rating indicates that the unit consumes less energy compared to standard models, resulting in lower utility bills and a reduced environmental footprint. The 2HP13 is built for both cooling and heating applications, making it a versatile addition to any home or commercial space.

The Ducane 2HP13 utilizes a durable, all-aluminum coil that offers superior heat transfer capabilities and corrosion resistance. This enhances the unit's efficiency and longevity, ensuring that it continues to perform optimally over the years. The cabinet is constructed from heavy-duty steel with a baked-on powder coat finish, which provides an extra layer of protection against the elements and ensures that the unit maintains its aesthetic appeal.

In terms of indoor comfort, the Ducane 2HP13 employs a high-efficiency scroll compressor. This technology reduces noise levels and improves overall performance, ensuring that your indoor environment remains quiet and comfortable. Additionally, the compressor is equipped with built-in protective features that help safeguard it from potential operational issues, extending its lifespan.

The 2HP13 model also includes a reliable multi-speed blower motor that enhances airflow within the system. This allows for adjustable performance levels which can be tailored to the specific needs of the space, contributing to improved energy efficiency. The unit also supports diagnostic capabilities, allowing for easy maintenance and repair, minimizing downtime in case of any issues.

Furthermore, the Ducane 2HP13 is designed with a user-friendly interface that makes it easy for homeowners to operate. It also integrates seamlessly with various smart thermostats to enhance system control and contribute to even greater energy savings.

In summary, the Ducane 2HP13 embodies a perfect balance of efficiency, reliability, and user-friendly features. Its durable construction, advanced compressor technology, and high-performance capabilities make it an excellent choice for anyone looking to enhance their indoor climate while minimizing their energy consumption. With its strong reputation in the HVAC industry, Ducane ensures that the 2HP13 meets the needs of modern homeowners and businesses alike.