Ducane (HVAC) 2HP13 warranty Do Locate the Unit, Do not Locate the Unit

Page 3

Elevate Unit

Accumulation of water and ice in base pan may cause equipment damage.

Elevate unit per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit. Use snow stand in areas where prolonged freezing temperatures are encountered.

If conditions or local codes require the unit be attached to pad or mounting frame, tie down bolts should be used and fastened through knockouts provided in unit base pan.

Roof Top Installations

Mount on level platform or frame 6 inches above roof surface. Place unit above a load-bearing wall and isolate unit and tubing set from structure. Arrange supporting members to adequately support unit and minimize transmission of vibration to building. Ensure roof structure and anchoring method is adequate for location. Consult local codes governing rooftop applications.

Roof mounted units exposed to winds above 5 mph may require wind baffles to achieve adequate defrost. A sheet metal baffle should be spaced 6-1/2" from the fall of the coil. The height should cover the face of the coil and the length should be 6" from the access panel.

NOTE: Unit must be level to within ± 2/ (± 3/8 in./ft) per

compressor manufacturer specifications.

Clearance Requirements

When installing, allow sufficient space for airflow clearance, wiring, refrigerant piping, and service. For proper airflow, quiet operation and maximum efficiency. Position so water, snow, or ice from roof or eaves cannot fall directly on unit.

DO LOCATE THE UNIT:

!With proper clearances on sides and top of unit

!On a solid, level foundation or pad

!To minimize refrigerant line lengths

DO NOT LOCATE THE UNIT:

!On brick, concrete blocks or unstable surfaces

!Near clothes dryer exhaust vents

!Near sleeping area or near windows

!Under eaves where water, snow or ice can fall directly on the unit

!with clearance less than 2 ft. from a second unit

!with clearance less than 4 ft. on top of unit

Operating Ambient

The minimum outdoor operating ambient in cooling mode is 55/F, and the maximum outdoor operating ambient in cooling mode is 125/F. The maximum outdoor operating ambient in heating mode is 66/F.

Indoor Coil Piston Selection

The outdoor heat pump section must be matched to a factory approved indoor section. It is mandatory that the installer ensure that the correct piston is installed in the indoor section. If necessary remove the existing piston and replace it with the correct piston See indoor unit instructions for details of changing the piston. Contact your distributor for accessory piston kits.

Indoor (Cooling) Piston Size

13 SEER Heat Pump Indoor Piston Sizes

Unit Size

Piston Size

18

.055

24

.063

30

.068

36

.076

42

.076

48

.082

60

.098

The evaporator coil may use an expansion valve (TXV) in place of piston.

14 SEER Heat Pump Models

All 14 SEER heat pump models are only rated with TXV on the indoor side.

14 SEER Heat Pump Indoor TXV

Unit Size

TXV Kit

18 thru 36

TXV3

42 thru 48

TXV5

Refrigeration Line Sets

Use only refrigerant grade copper tubes. Split systems may be installed with up to 50 feet of line set (no more than 20 feet vertical) without special consideration (see long line set guidelines).

100402-07

Issue 0733

Page 3 of 18

Image 3
Contents Table of Contents Unit Location & Installation Install on a Solid, Level Mounting PadOutdoor Section Do not Locate the Unit Do Locate the UnitEvacuating And Charging Instructions Installation of Line SetsRecommended Liquid & Vapor Tube Diameters Leak CheckElectrical Connections Opening Service ValvesInstall Electrical Accessories Control WiringEmergency Heat heating heat pump Start-Up ProcedureAdjusting Charge Refrigeration Charge AdjustmentSystem Operation Defrost Control board Diagnostic LED Time DelayPressure Switch Circuit Diagnostic LedsSingle Phase Wiring Diagram 3 Phase Wiring Diagram Heating Mode Pressures 2HP13B,L24P-1A Required Superheat for 2HP13 B,L18P-1ARequired Superheat for 2HP13 B,L24P-1A Required Superheat for 2HP13 B,L36P-1A Heating Mode Pressures 2HP13B,L30P-1AHeating Mode Pressures 2HP13B,L36P-1A Required Superheat for 2HP13 B,L30P-1ARequired Superheat for 2HP13 B,L48P-1A Heating Mode Pressures 2HP13B,L42P-1AHeating Mode Pressures 2HP13B,L48P-1A Required Superheat for 2HP13 B,L42P-1ARequired Superheat for 2HP13 B,L60P-1A Heating Mode Pressures 2HP13B,L60P-1ASystem Switch Case of extended power outageTemperature Setting Levers Fan SwitchIndoor Coil Regular Maintenance RequirementsImportant System Information Air FilterCompany will not be Responsible for These Warranties Apply onlyIssue

2HP13 specifications

Ducane, a well-respected name in the HVAC industry, offers a range of innovative heating, ventilation, and air conditioning solutions. One standout model in their lineup is the Ducane 2HP13, a 13 SEER central air conditioning unit that combines efficiency, reliability, and advanced technology to create comfortable indoor climates.

One of the main features of the Ducane 2HP13 is its efficient 13 SEER rating, which stands for Seasonal Energy Efficiency Ratio. This rating indicates that the unit consumes less energy compared to standard models, resulting in lower utility bills and a reduced environmental footprint. The 2HP13 is built for both cooling and heating applications, making it a versatile addition to any home or commercial space.

The Ducane 2HP13 utilizes a durable, all-aluminum coil that offers superior heat transfer capabilities and corrosion resistance. This enhances the unit's efficiency and longevity, ensuring that it continues to perform optimally over the years. The cabinet is constructed from heavy-duty steel with a baked-on powder coat finish, which provides an extra layer of protection against the elements and ensures that the unit maintains its aesthetic appeal.

In terms of indoor comfort, the Ducane 2HP13 employs a high-efficiency scroll compressor. This technology reduces noise levels and improves overall performance, ensuring that your indoor environment remains quiet and comfortable. Additionally, the compressor is equipped with built-in protective features that help safeguard it from potential operational issues, extending its lifespan.

The 2HP13 model also includes a reliable multi-speed blower motor that enhances airflow within the system. This allows for adjustable performance levels which can be tailored to the specific needs of the space, contributing to improved energy efficiency. The unit also supports diagnostic capabilities, allowing for easy maintenance and repair, minimizing downtime in case of any issues.

Furthermore, the Ducane 2HP13 is designed with a user-friendly interface that makes it easy for homeowners to operate. It also integrates seamlessly with various smart thermostats to enhance system control and contribute to even greater energy savings.

In summary, the Ducane 2HP13 embodies a perfect balance of efficiency, reliability, and user-friendly features. Its durable construction, advanced compressor technology, and high-performance capabilities make it an excellent choice for anyone looking to enhance their indoor climate while minimizing their energy consumption. With its strong reputation in the HVAC industry, Ducane ensures that the 2HP13 meets the needs of modern homeowners and businesses alike.