Ducane (HVAC) 2HP13 warranty Unit Location & Installation, Outdoor Section

Page 2

NOTE TO INSTALLING DEALER

These instructions and warranty are to be given to the owner or displayed near the indoor air handler unit.

This product and/or the indoor unit that is matched with may contain fiberglass wool.

Disturbing the insulation during installation, maintenance, or repair will expose you to fiberglass wool dust. (Fiberglass wool is known to the State of California to cause cancer.)

Fiberglass wool may also cause respiratory, skin, and eye irritation.

To reduce exposure to this substance or for further information, consult material safety data sheets available from your distributor.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label. Electrical shock can cause personal injury or death.

Safety Precautions

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warning or cautions attached to the unit.

1.Always wear proper personal protection equipment.

2.Always disconnect electrical power before removing panel or servicing equipment.

3.Keep hands and clothing away from moving parts.

4.Handle refrigerant with caution, refer to proper MSDS from refrigerant supplier.

5.Use care when lifting, avoid contact with sharp edges.

UNIT LOCATION & INSTALLATION

NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.

1.Locate unit away form windows, patios, decks, etc. where unit operation sounds may disturb customer.

2.Ensure that vapor and liquid tube diameters are appropriate to capacity of unit.

3.Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.

4.Leave some slack between structure and unit to absorb vibration.

5.When passing refrigerant tubes through the wall, seal opening with RTV or other silicon-based caulk.

6.Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, walls, and any structure.

7.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing.

8.Ensure that tubing insulation is pliable and completely surrounds vapor tube.

When outdoor unit is connected to factory-approved indoor unit, outdoor unit contains system refrigerant charge for operation with indoor unit of the same size when connected by 15 ft. of field-supplied tubing. For proper unit operation, check refrigerant charge using charging information located on control box cover.

IMPORTANT: Maximum liquid-line size is 3/8 in. O.D. for all residential applications including long lines.

Outdoor Section

Zoning ordinances may govern the minimum distance the condensing unit can be installed from the property line.

Install on a Solid, Level Mounting Pad

The outdoor section is to be installed on a solid foundation. This foundation should extend a minimum of 2" (inches) beyond the sides of the outdoor section. To reduce the possibility of noise transmission, the foundation slab should NOT be in contact with or be an integral part of the building foundation.

100402-07

Issue 0733

Page 2 of 18

Image 2
Contents Table of Contents Outdoor Section Unit Location & InstallationInstall on a Solid, Level Mounting Pad Do Locate the Unit Do not Locate the UnitLeak Check Installation of Line SetsRecommended Liquid & Vapor Tube Diameters Evacuating And Charging InstructionsControl Wiring Opening Service ValvesInstall Electrical Accessories Electrical ConnectionsRefrigeration Charge Adjustment Start-Up ProcedureAdjusting Charge Emergency Heat heating heat pumpSystem Operation Diagnostic Leds Time DelayPressure Switch Circuit Defrost Control board Diagnostic LEDSingle Phase Wiring Diagram 3 Phase Wiring Diagram Required Superheat for 2HP13 B,L24P-1A Heating Mode Pressures 2HP13B,L24P-1ARequired Superheat for 2HP13 B,L18P-1A Required Superheat for 2HP13 B,L30P-1A Heating Mode Pressures 2HP13B,L30P-1AHeating Mode Pressures 2HP13B,L36P-1A Required Superheat for 2HP13 B,L36P-1ARequired Superheat for 2HP13 B,L42P-1A Heating Mode Pressures 2HP13B,L42P-1AHeating Mode Pressures 2HP13B,L48P-1A Required Superheat for 2HP13 B,L48P-1AHeating Mode Pressures 2HP13B,L60P-1A Required Superheat for 2HP13 B,L60P-1AFan Switch Case of extended power outageTemperature Setting Levers System SwitchAir Filter Regular Maintenance RequirementsImportant System Information Indoor CoilThese Warranties Apply only Company will not be Responsible forIssue

2HP13 specifications

Ducane, a well-respected name in the HVAC industry, offers a range of innovative heating, ventilation, and air conditioning solutions. One standout model in their lineup is the Ducane 2HP13, a 13 SEER central air conditioning unit that combines efficiency, reliability, and advanced technology to create comfortable indoor climates.

One of the main features of the Ducane 2HP13 is its efficient 13 SEER rating, which stands for Seasonal Energy Efficiency Ratio. This rating indicates that the unit consumes less energy compared to standard models, resulting in lower utility bills and a reduced environmental footprint. The 2HP13 is built for both cooling and heating applications, making it a versatile addition to any home or commercial space.

The Ducane 2HP13 utilizes a durable, all-aluminum coil that offers superior heat transfer capabilities and corrosion resistance. This enhances the unit's efficiency and longevity, ensuring that it continues to perform optimally over the years. The cabinet is constructed from heavy-duty steel with a baked-on powder coat finish, which provides an extra layer of protection against the elements and ensures that the unit maintains its aesthetic appeal.

In terms of indoor comfort, the Ducane 2HP13 employs a high-efficiency scroll compressor. This technology reduces noise levels and improves overall performance, ensuring that your indoor environment remains quiet and comfortable. Additionally, the compressor is equipped with built-in protective features that help safeguard it from potential operational issues, extending its lifespan.

The 2HP13 model also includes a reliable multi-speed blower motor that enhances airflow within the system. This allows for adjustable performance levels which can be tailored to the specific needs of the space, contributing to improved energy efficiency. The unit also supports diagnostic capabilities, allowing for easy maintenance and repair, minimizing downtime in case of any issues.

Furthermore, the Ducane 2HP13 is designed with a user-friendly interface that makes it easy for homeowners to operate. It also integrates seamlessly with various smart thermostats to enhance system control and contribute to even greater energy savings.

In summary, the Ducane 2HP13 embodies a perfect balance of efficiency, reliability, and user-friendly features. Its durable construction, advanced compressor technology, and high-performance capabilities make it an excellent choice for anyone looking to enhance their indoor climate while minimizing their energy consumption. With its strong reputation in the HVAC industry, Ducane ensures that the 2HP13 meets the needs of modern homeowners and businesses alike.