Fedders A6V05S2B Troubleshooting Guide, Occurrence Possible Cause Solutions, Service

Page 7

SERVICE

TROUBLESHOOTING

Service To save time and expense, check the following before calling an authorized service station.

Insufficient Cooling

Shut all windows and doors in room.

Remove any obstructions from inside and outside louvers.

Close Air Exchanger.

Inspect filter and clean if dirty.

Under certain conditions the cooling coils directly behind the filter, may ice up and block the airflow. This is a common occurrence in air conditioners caused when the outside temperature drops below 70°F (21°C) while the humidity remains high. If this happens, simply turn the unit off and allow the ice to melt, then resume normal operation.

For Models Installed in North America - If Service or Parts are Required First, make the recommended checks. If it appears that

service or parts are still required, see your room air conditioner warranty “How to Obtain Warranty Service or Parts”.

For Models Installed Outside North America For room air conditioners purchased for use outside North America, the manufacturer does not extend any warranty either expressed or implied. Consult your local dealer for any warranty terms extended by the importer in your country.

Proper use and care of your air conditioner will help ensure longer life of the unit. It is recommended to annually inspect and clean the coils and condensate water passages. Expense of annual inspection is the consumer’s responsibility.

Troubleshooting Guide

 

Occurrence

Possible Cause

Solutions

 

Air conditioner will not operate

• Wall plug disconnected.

Push plug firmly into wall outlet.

 

 

• House fuse blown or circuit breaker tripped.

Replace fuse with time delay type

 

 

 

or reset circuit breaker.

 

 

• Unit turned off and then on too quickly.

Wait 3 minutes before restarting.

 

 

• Thermostat set too low for cooling.

Adjust thermostat to lower temperature.

 

Air from unit does not

• Unit in Fan mode.

Set Mode to Cool.

 

feel cold enough

• Temperature set too high.

Set thermostat to lower temperature.

 

 

• Room temperature below 70°F.

Cooling may not occur until room

 

 

 

temperature rises above 70°F.

 

 

 

 

 

Air conditioner cooling,

• Outdoor temperature below 70°F.

To defrost the coil, set mode to Fan.

 

but room is too warm —

 

Then, set thermostat to warmer temperature.

 

ice forming on cooling coil

• Dirty air filter — air restricted.

Clean filter. See “Cleaning the Air Filter” section.

 

behind decorative front

 

To defrost, set mode to Fan.

 

 

 

 

 

Air conditioner cooling,

• Dirty air filter — air restricted.

Clean air filter.

 

but room too warm —

 

Refer to “Cleaning Air Filter” section.

 

NO ice forming on cooling coil

• Thermostat set too warm.

Set thermostat to colder temperature.

 

behind decorative front

 

 

 

 

 

 

 

Noise when unit is cooling

• Air movement sound.

The sound of rushing air is normal. If too loud,

 

 

 

Fan Speed to Low setting.

 

 

• Sound of fan hitting water-

This is normal when humidity is high.

 

 

moisture removal system.

Close doors, windows and registers.

 

 

• Window vibration — poor installation.

Refer to installation instructions —

 

 

 

check with installer.

 

Water dripping inside

• Improper installation.

Tilt air conditioner slightly to the outside to

 

when unit is cooling

 

allow water drainage. Refer to installation

 

 

 

instructions — check with installer.

 

Water dripping outside

• Unit removing large quantity of moisture

This is normal during excessively humid days.

 

when unit is cooling

from humid room.

 

7

Image 7
Contents Para referencia futura For Future ReferencePour consultation ultérieure Or email customerservice@fedders.com InstallationImportant Grounding Requirements Tools Needed Sliding Window InstallationInstallation Parts Kit Fastener Identification Before you startFiller Panel Directing Airflow Casement Window InstallationCleaning Air Filter Installation in Wood Sliding or Wood Casement WindowsElectronic Control Panel Insufficient Cooling Troubleshooting GuideOccurrence Possible Cause Solutions ServiceExceptions How to Obtain Warranty Service or PartsRoom Air Conditioner Warranty WarrantyInstalacion Cordón con dispositivo de detecciónDe arco eléctrico Riesgo de Choque EléctricoIdentificación de Partes De Instalación Instalación en ventana corredizaRequisitos de la ventana Herramientas necesariasInstalacion Orientación de la corriente de aire Fig Instalación en ventana de hoja batienteLimpieza del filtro de aire Fig Control de modo Pantalla de configuración de temperatura/relojControl de alimentación Control del reloj Controles de temperatura/hora del relojLocalización y Solución de Averías Problema Causa Posible SolucionesServicio Excepciones Cómo obtener servicio o piezas bajo la garantíaGarantía del acondicionador de aire Servicio Y GarantiaCordon électrique avec dispositif de détection darc Risque de choc électriqueOutillage nécessaire Contenu de l’ensemble d’installation ’té Nom de la pièceCaractéristiques des fenêtres Montage dans une fenêtre coulissanteJoint de mousse Orientation de l’air Montage dans une fenêtre à battantsNettoyage du filtre à air Commande de la vitesse de ventilation Commande marche/arrêtCommandes de la température et du nombre d’heures Commande du modeDépannage Guide de diagnosticSymptôme Causes possibles Solutions Télécommande de Climatiseur800 332-6658 ou en écrivant à Pour les modèles installés en dehors de l’Amérique du NordGarantie du climatiseur GarantiePage Features / Características / Caractéristiques

A6V05S2B specifications

The Fedders A6V05S2B is a versatile and efficient air conditioning unit that has garnered attention for its impressive performance and innovative features. Designed to provide optimal comfort in various environments, this model is ideal for both residential and commercial applications.

One of the main features of the Fedders A6V05S2B is its high cooling capacity. With a cooling output of 5,000 BTU, this unit can effectively cool rooms up to 200 square feet, making it suitable for living rooms, small offices, and bedrooms. The unit's energy efficiency is another defining characteristic, boasting an Energy Efficiency Ratio (EER) that meets or exceeds industry standards. This means lower electricity bills and reduced environmental impact, making it an attractive choice for eco-conscious consumers.

The unit employs advanced technologies such as a rotary compressor and a refrigerant that complies with environmental regulations. The rotary compressor ensures a quieter operation while maintaining a consistent temperature, enhancing user comfort. Additionally, the Fedders A6V05S2B is designed with a convenient electronic control system that allows users to easily adjust settings. The digital display and remote control make operating the air conditioner effortless.

Another significant feature is the multiple cooling and fan speeds available with the unit. Users can select from high, medium, and low fan speeds, allowing for customized airflow tailored to individual preferences. The unit also includes a programmable timer that can be set to turn the AC on or off at specific times, promoting convenience and energy savings.

Moreover, the Fedders A6V05S2B is equipped with a washable air filter, which helps maintain indoor air quality by trapping dust, allergens, and other particles. Regular maintenance of the filter ensures optimal performance and longevity of the unit.

The sleek design of the A6V05S2B allows it to blend seamlessly into various decor styles, while the lightweight construction facilitates easy installation. With a range of features designed for user convenience and comfort, the Fedders A6V05S2B stands out as an excellent choice for those seeking reliability and efficiency in their cooling solutions.