Pentair CP12, XLS800 Automatic Pool Vacuums, Professional Service, Typical Automatic Pool Cleaner

Page 17

AUTOMATIC POOL VACUUMS

Automatic pool cleaners will decrease the water flow by restricting the suction of the circulation pump. Most automatic type pool cleaners operate from the suction provided by the circulation pump.

Some automatic pool vacuums are plugged into the skimmer suction port. The main floor drain is then re- stricted some, so that the auto vac has enough vacuum to operate. It can then move freely and not become stuck to the main drain port.

Typical

Automatic

Pool Cleaner

Often times, when these auto vacuums begin to wear, they require more suction from the pump to operate. Diverting all vacuum through the auto vac may help it run better but will restrict the overall water flow through the entire system and the heater.

If you have a low water flow situation where the heater is not getting enough water through the condenser coil, remove the pool vac and open all skimmer and main floor drain vacuum valves to provide maximum flow.

The auto vac manufacturer has a special valve that plugs into the skimmer before the auto vac hose. These spe- cial valves will properly regulate the water flow through the auto vac without creating too much vacuum restric- tion on the skimmer suction port.

The hose connecting the auto vac to the skimmer should be checked for the presence of suction leaks that allow air into the system. (See damage caused by vacuum leaks previously). As the auto vac hose gets older and sun damaged, it may develop an air vacuum leak or known as a "suction leak".

In all cases, you should do what ever necessary to gain the proper water flow through the heat exchanger. Once the pool vac is working, make sure you have the proper water flow through the heater at all times. If the low flow created by an auto vac is causing a problem with the unit, it is not considered a warranty condition.

CAUTION

When manually vacuuming the pool or performing ser- vice to the filtering system, "shut the heater off !" When the vacuum hose is plugged in, it may cause the pump to loose prime due to the air in the hose. You may also need to restrict the main drain suction port to gain more vacuum to the vacuum hose and head. This will lower the overall flow through the unit and cause it to cycle on & off, possibly causing damage. Shut the heater off whenever there is a chance of restricted wa- ter flow or loss of prime.

PROFESSIONAL SERVICE

As part of routine maintenance you should schedule a licensed air conditioning contractor or the factory ser- vice department to check the refrigeration circuit and components of the heat pump against factory specifica- tions. An improper adjustment or diagnosis by others may limit your warranty. You can call the factory ser- vice department for a list of factory authorized service centers in your area. Have all the refrigeration compo- nents checked against the factory specifications. You can request this information from the factory service department.

Verify correct installation according to the owners and installation manuals. Verify water flow through the heat exchanger and filtering system. Check all chlorinator placement and pool water balance. Test the supply volt- age, amperage draw, wire size against factory specifi- cations and local codes. Test the operating refrigerant pressures and corresponding components to factory specifications. Adjust refrigerant according to the sub cooling reading and factory specification.

Clean and flush the evaporator coils to remove debris, salt and mineral build up at least twice a year. Clean more often if you live in a costal and or sandy environ- ment. Clean them with a mild soap and a very soft brush. Do not use a pressurized garden hose. The air handling compartment below the fan must be cleaned of debris regularly. Contact an air conditioning con- tractor for proper methods of cleaning the evaporator coils. Remember to make sure the irrigation sprinkler system does not spray on the unit!

The fan motor should be oiled when the unit is serviced otherwise once per year or more if needed. Coastal in- stallation should oil the fan motor 4 times per year or

17 more depending on exposure.

Image 17
Contents Revision #A HydroTemp Manufacturing Co., Inc For Your Safety Read Before OperatingOwners Section Table of Contents Return on Investment LOW MaintenanceHeat Pump Efficiency Longer Swimming SeasonInch Plumbing With Internal Automatic Bypass Up To 90 GPM Clean refrigerantTrane Compressor With 410-A, the safeAutomatic Design AdvantagesInternal Thermostat Dual Thermostat Control PanelD. Status Light Panel D. Status LightsD. Status Light Panel To use indicator lights see Troubleshooting guide pages 26Advise Your Pool Service CO Clean Filtering System Compressor Time DelayWater Pressure Switch Turn T-STAT ALL the WAY DownThermostat Control & Settings for Thermostat Control & Settings Evaporator AIR CoilHeat & Cool Models Heat ExchangerSET Thermostat to Maximum Common Mechanical TimerThermostat will now be set at 80 degrees F Thermostat SettingPool Surface Reradiation Convection Evaporation WindConduction Warm Pool Water Pool ShellCovers Save Time & Money Controlling Heat LossSpas Heating Tips Typical Pool Blanket & RollerSprinklers Owners Maintenance & CarePlants Condensation DrainsAIR Flow CleaningRoof RUN OFF Water Piping Leak ?Water Flow Filter Cleaning & CareCirculation Pump Vacuum & Pressure LeaksAutomatic Pool Vacuums Professional ServiceTypical Automatic Pool Cleaner Plumbing & Water Flow See chlorinator Placement guidelinesPlumbing Connections Internal Automatic BypassStalled with all types of chlorinators to prevent chlorine High Rate Water PumpsChemical resistant check valve and loop must be Sacrificial Water Fittings Standard Pool Water Balance RequirementsAdvanced Heat Exchanger Design Heat Exchanger Cross SectionChlorines Effect on pH ChlorineVacuum Leaks Protect Heat ExchangerChlorine Migration Adding Chemicals Chlorinator PlacementNo chemicals or chlorine tablets in the skimmer Absolutely no chemicals in the skimmerCommercial Feeders Chemical Application for SpasLong Term Freeze Protection / Drain Valve Installation Short Term Freeze Protection ProceduresCondition Possible Cause Possible Remedy Owner Trouble Shooting GuideRisk of electrical shock or electrocution Motor valve. Call your installer for advise. Call Mandatory Bonding to Pool Steel Electrical Wiring SpecificationsUnit Identification HOW to GET Service Glossary of Terms Page Page Page This page is blank This page is blank Heat Pumps

XLS1000, XLS800, XLS600, HP 400, HP 600, HP 800, HP 1000, HP 230, CP12 specifications

Pentair is a recognized leader in providing innovative filtration and pumping solutions, and among its noteworthy offerings are the CP12, HP 400, HP 600, HP 800, HP 1000, HP 230, XLS600, XLS800, and XLS1000 models. Each of these products is designed with unique features and advanced technologies that meet diverse customer needs across various applications.

The Pentair CP12 is a compact and efficient pump designed for residential water management. Known for its ease of installation and reliable performance, the CP12 incorporates a high-efficiency motor that minimizes energy consumption while ensuring effective water circulation.

Moving to the HP series, the HP 400, 600, 800, and 1000 models boast powerful performance characteristics suited for heavy-duty applications. These pumps are engineered with robust materials for longevity and durability. With advanced hydraulic designs, they deliver excellent flow rates and pressure, making them ideal for applications like irrigation, water feature management, and even light industrial use. The HP series also features smart technology that allows for remote monitoring and control, enhancing operational efficiency.

In the mid-range, the HP 230 model offers versatility with its multi-purpose capabilities. Designed for residential and light commercial use, it strikes a perfect balance between performance and energy efficiency, ensuring optimal operation without excessive energy costs.

The XLS series, which includes the XLS600, XLS800, and XLS1000 models, targets larger commercial applications. These models are equipped with cutting-edge technology designed for superior flow and pressure management, making them perfect for high-capacity requirements. Their variable speed operation allows for customizable performance tailored to specific system needs, while advanced monitoring capabilities enhance reliability and maintenance scheduling.

All of these Pentair pumps prioritize environmental responsibility with energy-efficient designs that reduce carbon footprints. Key features across the range include corrosion-resistant materials, thermal protection for added safety, and user-friendly interfaces that simplify operation and monitoring.

In conclusion, Pentair’s CP12, HP series, and XLS series pumps stand out due to their innovative technologies, impressive performance capabilities, and commitment to energy efficiency. Whether for residential or commercial applications, these models cater to a wide range of needs, ensuring customers can find effective solutions for their water management challenges.