Pentair XLS600, XLS800, XLS1000 Return on Investment, Heat Pump Efficiency, Longer Swimming Season

Page 3

WARNING

THE MISUSE OF THIS PRODUCT CAN RESULT IN SEVERE INJURY, DEATH,

OR PROPERTY DAMAGE. BE ADVISED OF THE FOLLOWING CONDI-

TIONS THAT MAY EXIST:

1.ELECTROCUTION AND/OR FIRE DUE TO IMPROPER WIRING.

2.HAND AND HAIR ENTRAPMENT MAY OCCUR NEAR THE FAN LO- CATED ON THE TOP OF THIS UNIT.

3.LOSS OF POOL WATER AND/OR FLOODING AND/OR PROPERTY DAM- AGE.

4.DAMAGE AND/OR MISUSE TO THE PRODUCT RESULTING IN FAILURE OR EXCESSIVE WEAR.

5.ALL ELECTRICAL WORK BY LICENSED PROFESSIONAL ONLY.

Owners/users should contact the factory service department for advice at:

HYDROTEMP MANUFACTURING CO., INC. 12155 Metro Pkwy, Ste. 5

Ft Myers, FL 33912

 

RETURN ON INVESTMENT

(941) 768-1555

 

The costs of installing a heat pump are somewhat higher

(941) 768-2856 (fax)

 

 

than a gas heater but you will save enough in opera-

www.warmpool.com

tional costs to offset the difference, probably in the first

 

 

 

year or two. After a few heating seasons you will have

 

 

 

saved enough, compared to LP gas heat, to pay for the

HEAT PUMP EFFICIENCY

entire heat pump and installation

Your new highly efficient heat pump pool/spa heater

.

LONGER SWIMMING SEASON

will deliver warm pool water for your comfort for pen-

 

nies a day. For every dollar you spend to run your heat

A heat pump is the least expensive way to heat your

pump, you will receive between $4.00 and $5.00 worth

pool. It will out perform solar by delivering heat on

of heat in return. The heat pump transfers the heat from

demand, no matter how much sunshine is available. A

the outside air

to your pool or spa. Your heat pump

solar system with a gas back L.P. Gas back up will cost

costs about 60 to 75 percent less than L.P. Gas heaters

more to operate than the heat pump alone.

to operate with less maintenance and gas storage tank

In Florida, a heat pump offers a full 12 months of swim-

is not needed. Your heat pump produces no pollution

ming season compared to a solar systems 10 month

and no pilot lights to deal with.

 

 

swimming season. A heat pump will provide higher

 

 

 

$2.34

Approximate

temperatures than a solar system. Solar will not heat a

Cost Per 100,000 Btu's of Heat

spa on demand after sundown & during inclement

 

 

$1.65

 

weather.

$1.10

 

 

LOW MAINTENANCE

 

$ 0.96

 

 

 

$ 0.32

Maintenance cost can be more for a gas heater, consid-

 

 

ering the fact that a gas heater starts to lose efficiency

 

 

 

Electric Oil

LP Gas Natural

Heat

as it gets older. The heat pump's sealed system needs

far less attention.

 

Gas

Pump

 

 

Image 3 Contents
Revision #A HydroTemp Manufacturing Co., Inc For Your Safety Read Before OperatingOwners Section Table of Contents Longer Swimming Season LOW MaintenanceReturn on Investment Heat Pump EfficiencyWith 410-A, the safe Clean refrigerantInch Plumbing With Internal Automatic Bypass Up To 90 GPM Trane CompressorDesign Advantages InternalAutomatic D. Status Lights Dual Thermostat Control PanelThermostat D. Status Light PanelD. Status Light Panel To use indicator lights see Troubleshooting guide pages 26Turn T-STAT ALL the WAY Down Compressor Time DelayAdvise Your Pool Service CO Clean Filtering System Water Pressure SwitchHeat Exchanger Thermostat Control & Settings Evaporator AIR CoilThermostat Control & Settings for Heat & Cool ModelsSET Thermostat to Maximum Common Mechanical TimerThermostat will now be set at 80 degrees F Thermostat SettingWarm Pool Water Pool Shell Reradiation Convection Evaporation WindPool Surface ConductionTypical Pool Blanket & Roller Controlling Heat LossCovers Save Time & Money Spas Heating TipsCondensation Drains Owners Maintenance & CareSprinklers PlantsWater Piping Leak ? CleaningAIR Flow Roof RUN OFFVacuum & Pressure Leaks Filter Cleaning & CareWater Flow Circulation PumpProfessional Service Typical Automatic Pool CleanerAutomatic Pool Vacuums Internal Automatic Bypass See chlorinator Placement guidelinesPlumbing & Water Flow Plumbing ConnectionsHigh Rate Water Pumps Chemical resistant check valve and loop must beStalled with all types of chlorinators to prevent chlorine Heat Exchanger Cross Section Standard Pool Water Balance RequirementsSacrificial Water Fittings Advanced Heat Exchanger DesignChlorines Effect on pH ChlorineProtect Heat Exchanger Chlorine MigrationVacuum Leaks Absolutely no chemicals in the skimmer Chlorinator PlacementAdding Chemicals No chemicals or chlorine tablets in the skimmerCommercial Feeders Chemical Application for SpasLong Term Freeze Protection / Drain Valve Installation Short Term Freeze Protection ProceduresOwner Trouble Shooting Guide Risk of electrical shock or electrocutionCondition Possible Cause Possible Remedy Motor valve. Call your installer for advise. Call Electrical Wiring Specifications Unit IdentificationMandatory Bonding to Pool Steel HOW to GET Service Glossary of Terms Page Page Page This page is blank This page is blank Heat Pumps