SHUT DOWN & FREEZE PROTECTION PROCEDURES

When shutting the unit down for the end of the swimming season you must consider some items to protect the unit from inclement weather. It is best in most situations to shut the unit off by turning the thermostat all the way down, to the "left". Leave power ,(circuit breaker), to the unit “on” unless the pool or spa water temperature drops below 50 degrees F. If you shut off the main power supply due to freezing conditions, be sure to preheat the compressor for 8 hours before attempting to start the heater.

SHORT TERM FREEZE PROTECTION PROCEDURES

When the outside air temperature is forecast to drop below 32 degrees F for a short time:

You should set the circulation pump timer to run 24 hours per day in order to circulate water through the unit and filtration system. Standing water inside the unit will freeze and damage the units heat exchanger and refrigerant system.

Shut the heat pump off and do not try to heat the pool during freezing temperatures. If the unit is left running it may ice up and the compressor will stop running. The defrost control inside the unit will shut the compressor off but allow the fan to run. The fan will circulate air through the unit to help defrost the evaporator air coil. If you know that the temperatures are going to be below 36 degrees F, you should eliminate the possibility of icing and just shut the unit off. Do not use the circuit breaker as the “on”/“off” switch, but keep the water pump running.

LONG TERM FREEZE PROTECTION / DRAIN VALVE INSTALLATION

If you live in a climate that has a seasonal swim season due to winter, you should follow these long term freezing precautions.

Spigot Type

Drain Valves

OUT

IN

Shut Off

Valves

Shut the water pump off. Close both shut off valves. Open both drains and allow water to exit. Use pressurized air on the water in spigot only, to force the rest of the water out the other spigot.

If you live in an area that experiences freezing tempera- tures, the heat exchanger/water coil and bypass plumbing must have all water removed to prevent damage to the heat pump system. This procedure should be done prior to the first freeze along with your other pool winterizing routine. When you drain the filter system and piping you should in- clude the heat pump as well.

There should be two spigot type drains plumbed into the heaters water in and water out piping. Place these valves as close to the heater and at the lowest point possible so as much water will drain as possible. Install two shut off valves on the water in and out lines as shown here. The rest of the water should be blown out with pressurized air to insure all water is removed. A antifreeze designed for pool equipment may be used, see a local pool professional.

CAUTION

Do not add isolation valves unless you

intend to clear the heat exchanger of water with pressurized air. Stagnate water left in the heat exchanger can cause corrosion.

25

CAUTION

You may shut the circuit breaker off for the season as long as you remember to preheat the compressor next season before start up see start up procedures.

Image 25 Contents
Revision #A HydroTemp Manufacturing Co., Inc For Your Safety Read Before OperatingOwners Section Table of Contents Return on Investment LOW MaintenanceHeat Pump Efficiency Longer Swimming SeasonInch Plumbing With Internal Automatic Bypass Up To 90 GPM Clean refrigerantTrane Compressor With 410-A, the safeInternal Design AdvantagesAutomatic Thermostat Dual Thermostat Control PanelD. Status Light Panel D. Status LightsD. Status Light Panel To use indicator lights see Troubleshooting guide pages 26Advise Your Pool Service CO Clean Filtering System Compressor Time DelayWater Pressure Switch Turn T-STAT ALL the WAY DownThermostat Control & Settings for Thermostat Control & Settings Evaporator AIR CoilHeat & Cool Models Heat ExchangerSET Thermostat to Maximum Common Mechanical TimerThermostat will now be set at 80 degrees F Thermostat SettingPool Surface Reradiation Convection Evaporation WindConduction Warm Pool Water Pool ShellCovers Save Time & Money Controlling Heat LossSpas Heating Tips Typical Pool Blanket & RollerSprinklers Owners Maintenance & CarePlants Condensation DrainsAIR Flow CleaningRoof RUN OFF Water Piping Leak ?Water Flow Filter Cleaning & CareCirculation Pump Vacuum & Pressure LeaksTypical Automatic Pool Cleaner Professional ServiceAutomatic Pool Vacuums Plumbing & Water Flow See chlorinator Placement guidelinesPlumbing Connections Internal Automatic BypassChemical resistant check valve and loop must be High Rate Water PumpsStalled with all types of chlorinators to prevent chlorine Sacrificial Water Fittings Standard Pool Water Balance RequirementsAdvanced Heat Exchanger Design Heat Exchanger Cross SectionChlorines Effect on pH ChlorineChlorine Migration Protect Heat ExchangerVacuum Leaks Adding Chemicals Chlorinator PlacementNo chemicals or chlorine tablets in the skimmer Absolutely no chemicals in the skimmerCommercial Feeders Chemical Application for SpasLong Term Freeze Protection / Drain Valve Installation Short Term Freeze Protection ProceduresRisk of electrical shock or electrocution Owner Trouble Shooting GuideCondition Possible Cause Possible Remedy Motor valve. Call your installer for advise. Call Unit Identification Electrical Wiring SpecificationsMandatory Bonding to Pool Steel HOW to GET Service Glossary of Terms Page Page Page This page is blank This page is blank Heat Pumps