THREE PHASE INSTALLATION
If the motor on your machine is wired for 200, 230 or 460 Volts, Three Phase, proceed as follows when connecting your machine to an electrical power system.
1.Remove screw (A) Fig. 15, and terminal strip cover
(B).
B
A
Fig. 15
2.Remove plastic covering (C) Fig. 16, that snaps into terminal strip.
3.Bring three phase power line through access hole in bottom of terminal strip box and connect the three power lines to terminals (D) Fig. 17, and the green ground wire to ground screw (E).
The rotation of the cutterhead must be in a clockwise direction when viewed from the left side of the machine; that is, the knives must be rotating toward the infeed table from the top. If the cutterhead rotation is incorrect, disconnect the machine from the power source and interchange any two of the three incoming power lines connected to terminals (D) Fig. 17.
C
Fig. 16
D
E
Fig. 17
12