MOUNTING THE ROUTER

WARNING:

Always unplug router and remove router bits before mounting to router table. Remove the fence, the insert, the featherboards and the miter guide from the tabletop before mounting the router.

There are two methods for attaching routers to router table. The table will accept routers with bases up to 7" in diameter. See chart below to see whether your router will mount directly to the table or will require the use of the adapter plate provided.

NOTE: If your router is not one of those listed in the chart, place the adapter base plate on top of the router base plate and rotate until the holes in the two plates are aligned. When hole patterns line up, the mounting scheme has been identified.

Brand

Model #

Adapter

hole pattern

 

 

 

 

 

 

R160K, R160V

 

Ryobi®

R161K, R161KT

A/AB

R162K, R165

 

R180, R180PL

 

 

R1801M

 

 

 

 

 

690, 691

 

 

693LRPK

 

Porter Cable®

694VK, 892

D

893PK, 895PK

 

 

 

1001, 8931

 

 

9690LR

 

 

 

 

 

26941

 

Milwaukee®

5615-21

D

5616-21

 

 

 

5619-20

 

 

 

 

Hitachi®

KM12VC

D

 

 

 

Black & Decker®

7612

F

 

 

 

DeWalt®

DW 610

F

 

 

DW 616

D

 

 

 

 

 

1810, 1815

 

Skil®

1820, 1823

E

1825, 1835

 

 

 

1845-02

 

 

 

 

 

17504, 17505

 

 

17506, 17511

E

 

17515, 17528

Craftsman®

 

17533, 26834

 

 

 

 

 

27500, 27510

A

 

27511

 

 

 

 

 

NOTE: If your router does not fit adapter base plate or if you wish to mount router directly to the table for greater cutting depth, remove the base plate from your router, use it as a template, and drill directly through the tabletop.

I. Mounting Routers with 7"

Round Adapter Base Plate

See Figure 9 and 10

1.Remove the base plate from router.

2.Place the adapter base plate (K) on the router base according to mounting pattern identified in chart. See Figures 9.

3.Use the screws removed from the router base plate to attach the adapter base plate to the router base. Tighten screws securely.

4.Routers with A and AB hole pattern use three counter- sink 5/16" - 18 x 3/4" screws (X), to attach the adapter base plate (K) to the router. For Ryobi routers RE600 and RE601 use three M 8 x 20 countersink screws (Y).

5.To mount Craftsman routers that use the E-hole pat- tern to the adapter plate (K), three 10" - 32 x 1/2" coun- tersink screws are required (not provided).

NOTE: Adapter base plate must be mounted to the router using countersunk flat head screws.

X/Y (3)

K

X or Y

NOTE: Countersink screws

K

Fig. 9

12

Image 12
Contents OPERATOR’S Manual Save this Manual for Future ReferenceTable of Contents IntroductionRules for Safe Operation Unpacking and Checking Contents Features and Specifications Router Table features includePackage Contents and Hardware Legend Package Contents and Hardware Legend Description QTY Assembly Assembling the Router TableTo Attach the Switch BOX To Attach the FencesTo Attach Safety Shield Securing the Router TableAssemble the Miter Guide Mounting the Router Mounting Routers with Round Adapter Base PlateHole pattern Or YMounting the Router Switch BOX IntroductionElectrical Hookup Switch Box Familiarization Operation of Switch Box and RouterFor Routers With LOCK-ON Feature Circuit BreakerConnecting a Vacuum Using your router/router tableOperation Pencil line #1Using the router for beading Using the router as a jointerEdge cutting Left fence Right fence Knobs StraightedgeAdjusting the fence slides Routing without safety shield, and/or fenceInside routing Accessories Using miter guideOutside routing Using featherboard flaps Routing small workpiecesSmall workpiece Scrap piece Repair Parts Repair parts tabletop Key No Hardware bag 119900102Page Service Model no