Bryant 650A warranty Thermostats and Accessories, Accessory Usage Guideline

Page 6

THERMOSTATS AND ACCESSORIES

Thermostat—Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATBBNHP01-B

 

 

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATBBPHP01-B

 

 

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel, Includes Outdoor

 

Sensor (TSTATXXSEN01)

TSTATBBPDF01-B*

 

 

Thermidistat™ Control—Non-Programmable/Programmable Thermostat with Humidity

 

Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air

 

Temperature Sensor.)

TSTATBBPRH01-B*

 

 

Builder’s Thermostat—Manual Changeover, Non-Programmable, °F/°C, 2-Stage Heat,

 

1-Stage Cool, Heat Pump

TSTATBBBHP01*

 

 

Outdoor Air Temperature Sensor

TSTATXXSEN01

 

 

Backplate for Non-Programmable Thermostat

TSTATXXNBP01†

 

 

Backplate for Programmable Thermostat and Thermidistat™ Control

TSTATXXPBP01†

 

 

Backplate for Builder’s Thermostat

TSTATXXBBP01†

 

 

Thermostat Conversion Kit (4 to 5 Wire)—10 Pack

TSTATXXCNV10‡

 

 

* Do not use in zoning heat pump applications.

† This plate is designed to cover surrounding wall area located behind thermostat.

Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed.

**Outdoor air temperature sensor is an accessory for all Bryant electronic thermostats, except the non-programmable air conditioner version and builder’s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat.

The outdoor air temperature sensor must be used with the dual fuel thermostat.

The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.

ACCESSORY USAGE GUIDELINE

 

REQUIRED FOR LOW-AMBIENT

REQUIRED FOR LONG-LINE

 

APPLICATIONS

APPLICATIONS*

ACCESSORY

(Below 55°F)

(Over 50 Ft)

 

 

 

Crankcase Heater

Yes

Yes

 

 

 

Evaporator Freeze Thermostat

Yes

No

 

 

 

Compressor Start Assist—Capacitor and Relay

Yes

Yes

 

 

 

Puron Low-Ambient Pressure Switch

Yes

No

 

 

 

Wind Baffle

See Low-Ambient

No

Pressure Switch Instructions

 

 

 

 

 

Support Feet

Recommended

No

 

 

 

Puron Hard Shutoff TXV

Yes†

Yes†

 

 

 

Puron Liquid-Line Solenoid Valve for Heating

No

See Long-Line

Application Guideline

 

 

 

 

 

*For tubing line sets between 50 and 175 ft and/or 20 ft elevation difference between indoor and outdoor units, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using Puron Refrigerant.

† Required for all applications.

—6—

Image 6
Contents 650A 60 Hz Unit Unit Dimensions DimensionsDimensions Minimum MountingRecommended Tube Diameters Metering DeviceSpecifications ElectricalSpecifications Thermostats and Accessories Accessory Usage GuidelineService Alarm Low-Ambient Pressure SwitchOutdoor Air Temperature Sensor Time-Delay RelayCombination Ratings Combination Ratings 650A Balance Point Worksheet 650AN024-A,C,Outdoor Section With FX4ANF030 Indoor Section Evap Condenser Entering AIR Temperatures FDetailed Cooling Capacities EWB650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section Detailed Cooling Capacities650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section CFM EWB650AN042-A,C Outdoor Section With FV4ANF003 Indoor Section 650AN048-A,C Outdoor Section With FV4ANF005 Indoor SectionCapacity Power Section 650AN060-B,C Outdoor Section With FV4ANB006 Indoor SectionIndoor Cooling Section 650AN024-A,C Outdoor Section With FX4ANF030 Indoor Section Indoor Outdoor Coil Entering AIR Temperatures FHeat Pump Heating Performance EDB CFMMBtuh† Pwr Section Size Capacity PowerHeat Pump Heating Performance Size Capacity18.5 17.0 22.9 21.1 27.9 25.4 33.5 29.8 40.2 36.6 48.2 System Design Matched SystemPage Service Training Call for Free Catalog