Bryant 650A warranty Combination Ratings

Page 9

COMBINATION RATINGS Continued

 

 

 

 

 

 

 

ARI STANDARD RATINGS*

 

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

Heating

 

 

 

 

 

 

Seasonal Efficiency SEER

 

 

 

 

 

 

 

 

 

 

Factory-

 

 

Field-Supplied

 

High-Temp

Low-Temp

 

 

 

 

 

 

 

Accessory‡

 

 

 

 

 

 

UNIT

 

 

 

Supplied

 

 

 

 

 

 

 

 

SIZE-

INDOOR

 

 

Enhance-

Standard

Puron

PuronTXV

 

 

 

 

 

 

SERIES

UNIT

CFM††

TC

ment

Rating

 

TXV

& TDR**

EER

TC

COP

TC

COP

HSPF

 

CJ5A/CK5A/CK5BA060

1400

45,000

NONE

 

12.50

10.75

48,000

3.50

28,600

2.38

8.20

048-A,C

CJ5A/CK5A/CK5BN060

1400

45,500

NONE

 

13.00

10.90

48,500

3.52

28,600

2.38

8.25

CJ5A/CK5A/CK5BX060

1400

45,500

NONE

 

13.00

10.90

48,500

3.52

28,600

2.38

8.25

 

 

 

CK3BA060

1400

45,000

NONE

 

12.50

10.75

48,000

3.50

28,600

2.38

8.20

 

FV4ANB006†

1750

58,000

TDR&TXV

13.00

 

10.75

60,000

3.56

37,000

2.54

8.00

 

FB4ANB070

1750

57,000

TDR

 

12.00

10.20

60,000

3.44

37,800

2.46

7.80

060-B,C

FC4BNB070

1750

57,000

TDR

 

12.00

10.20

60,000

3.44

37,800

2.46

7.80

FK4CNB006

1750

58,000

TDR

 

12.80

10.75

59,500

3.56

37,000

2.54

8.00

 

FX4ANB060

1750

57,000

TDR&TXV

12.00

 

10.20

60,000

3.44

37,800

2.46

7.80

 

CC5A/CD5AW060

1750

56,000

NONE

 

12.50

10.45

58,500

3.26

36,800

2.42

7.50

 

CJ5A/CK5A/CK5BX060

1750

56,500

NONE

 

12.50

10.55

59,000

3.44

37,000

2.50

7.70

*Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit. High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.

Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.

Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.

‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.

** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.

Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.

†† Indoor Airflow

COP — Coefficient of Performance EER — Energy Efficiency Ratio

HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio

TC — Total Capacity (Btuh) TDR Time-Delay Relay

TXV — Thermostatic Expansion Valve

—9—

Image 9
Contents 650A 60 Hz Dimensions DimensionsUnit Unit Dimensions Minimum MountingMetering Device Recommended Tube DiametersElectrical SpecificationsSpecifications Accessory Usage Guideline Thermostats and AccessoriesOutdoor Air Temperature Sensor Low-Ambient Pressure SwitchService Alarm Time-Delay RelayCombination Ratings Combination Ratings 650A Balance Point Worksheet Detailed Cooling Capacities Evap Condenser Entering AIR Temperatures F650AN024-A,C,Outdoor Section With FX4ANF030 Indoor Section EWB650AN030-A,C Outdoor Section With FX4ANF030 Indoor Section Detailed Cooling Capacities650AN036-A,C Outdoor Section With FX4ANF042 Indoor Section CFM EWB650AN048-A,C Outdoor Section With FV4ANF005 Indoor Section 650AN042-A,C Outdoor Section With FV4ANF003 Indoor SectionCapacity Power Section 650AN060-B,C Outdoor Section With FV4ANB006 Indoor SectionIndoor Cooling Section Heat Pump Heating Performance Indoor Outdoor Coil Entering AIR Temperatures F650AN024-A,C Outdoor Section With FX4ANF030 Indoor Section EDB CFMHeat Pump Heating Performance Section Size Capacity PowerMBtuh† Pwr Size Capacity18.5 17.0 22.9 21.1 27.9 25.4 33.5 29.8 40.2 36.6 48.2 Matched System System DesignPage Call for Free Catalog Service Training