Bryant 280ANV installation instructions Installation Instructions, Table of Contents

Page 1

280ANV EVOLUTIONR EXTREME VARIABLE SPEED HEAT PUMP WITH PURONr REFRIGERANT (2 - 5 Ton)

Installation Instructions

NOTE: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS

PAGE NO.

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION RECOMMENDATIONS

. . . 3

INSTALLATION

3-11

Step 1 — Check Equipment and Jobsite

. . . 4

Step 2

— Install on Solid Pad

. . . 4

Step 3 — Clearance Requirements

. . . 4

Step 4 — Operating Ambient

. . . 4

Step 5 — Elevate Unit

. . . 4

Step 6 — Liquid Line Solenoid Valve (LSV)

. . . 4

Step 7

— Making Piping Connections

. 5-6

Step 8

— Make Electrical Connections

. . . 7

Step 9

— Compressor Crankcase Heater

. . . 7

Step 10 — Install Accessories

. . . 8

Step 11 — Start-Up

. . . 8

Step 12 — System Functions and Sequence of Operation

8-10

Step 13 — Check Charge

10-11

Step 14 — Pumpdown & Evacuation

. . 11

MAJOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-17

FINAL CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

PURONr REFRIGERANT QUICK REFERENCE GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Image 1
Contents Table of Contents Installation InstructionsInverter Cover Safety ConsiderationsInstallation Recommendations InstallationCheck Equipment and Job Site Unpack UnitClearance Requirements Install on a Solid, Level Mounting PadOperating Ambient Elevate UnitMake Piping Connections Accessory UsagePersonal Injury and Unit Damage Hazard Unit Damage HazardNo Installation of Adapter Tube Install Liquid-Line Filter Drier IndoorOutdoor Unit Connected to Factory-Approved Indoor Refrigerant Tubing connection OutdoorCompressor Crankcase Heater Make Electrical ConnectionsStart-Up Install AccessoriesSystem Functions And Sequence Of Operation Follow these steps to properly start up the systemDefrost Communication and Status Function LightsHeating Check Chart Procedure Check Charge Charge in Charging modePumpdown & Evacuation Evacuation and Recovery of Refrigerant from within 280ANVPump Down Major Components TroubleshootingControl Fault Pressure Switch Protection230V Line Power Disconnect Detection Temperature ThermistorsOutdoor Coil Thermistor Variable Speed Compressor Power Input TerminalsSuction Thermistor OST Variable Speed Compressor Sensor Output TerminalsExample Status CodesVariable Speed Control Board With optional Utility Relay Hours TroubleshootingFinal Checks Care and MaintenancePuronr R-410A Refrigerant Quick Reference Guide
Related manuals
Manual 4 pages 21.14 Kb

280ANV specifications

The Bryant 280ANV is a highly efficient air conditioning unit designed for residential use, providing homeowners with reliable cooling performance while maintaining energy efficiency. One of the standout features of the Bryant 280ANV is its two-stage compressor, which allows for variable speed operation. This means that the unit can adjust its cooling output to match the current demand for indoor comfort, leading to more consistent temperatures and increased energy savings.

The Bryant 280ANV also boasts an impressive SEER (Seasonal Energy Efficiency Ratio) rating, which indicates its energy efficiency. Typically, this model achieves a SEER rating of up to 20, making it a strong contender in the market for those looking to reduce their energy bills without sacrificing comfort. This level of efficiency not only results in lower monthly costs but also contributes to a reduced environmental footprint.

Another key technology featured in the Bryant 280ANV is its advanced, variable-speed blower motor. This motor helps to operate quietly while ensuring optimal airflow throughout the home. The quiet operation of the 280ANV means that it can deliver cooling without disturbing your daily life, making it an excellent choice for bedrooms or other quiet spaces.

The unit is also designed with durability in mind. Its cabinet is constructed from high-quality, weather-resistant materials that protect against harsh outdoor conditions. This ensures longevity and reliable performance over the years. Furthermore, the Bryant 280ANV includes a protected scroll compressor that adds an extra layer of reliability and enhances the unit's overall efficiency.

Installation of the Bryant 280ANV can be completed by a qualified HVAC professional, who can ensure that the system is set up to operate at peak performance. Additional features, such as the built-in Wi-Fi capability, allow homeowners to connect the unit to smart home systems for enhanced control and convenience.

In conclusion, the Bryant 280ANV combines energy efficiency with advanced technology to provide effective cooling solutions for residential spaces. With its two-stage compressor, high SEER rating, quiet operation, and durable construction, it meets the needs of modern homeowners who value comfort, efficiency, and reliability. Overall, the Bryant 280ANV stands out as a quality choice for those seeking a dependable air conditioning system.