Bryant 548J*14D Plan for Unit Location, Service Clearance Dimensional Drawing

Page 4

548J*14D

Fig. 1 - Unit Dimensional Drawing – Size 14 Unit (cont.)

C10364

INSTALLATION

Jobsite Survey

Complete the following checks before installation.

1.Consult local building codes and the NEC (National Electrical Code) ANSI/NFPA 70 for special installa- tion requirements.

2.Determine unit location (from project plans) or select unit location.

3.Check for possible overhead obstructions which may interfere with unit lifting or rigging.

18”

(457)*

42"

(1067)

42"

(1067)

42"

(1067)

Step 1 — Plan for Unit Location

*Required bottom condensate drain connection. Otherwise, 36” (914mm) for condensate connection.

C09897

Select a location for the unit and its support system (curb or other) that provides for at least the minimum clearances required for safety. This includes the clearance to combustible surfaces, unit performance and service access below, around and above unit as specified in unit drawings. See Fig. 2.

NOTE: Consider also the effect of adjacent units.

Unit may be installed directly on wood flooring or on Class A, B, or C roof-covering material when roof curb is used.

Do not install unit in an indoor location. Do not locate air inlets near exhaust vents , relief valves, or other sources of contaminated air.

Fig. 2 - Service Clearance Dimensional Drawing

Although unit is weatherproof, avoid locations that permit water from higher level runoff and overhangs to fall onto the unit.

Select a unit mounting system that provides adequate height to allow for removal and disposal of frost and ice that will form during the heating-defrost mode as well as allow installation of condensate trap per requirements. Refer to Step 9 — Install External Condensate Trap and Line – for required trap dimensions.

4

Image 4
Contents Installation Instructions Safety Considerations Unit Dimensional Drawing Size 14 Unit Service Clearance Dimensional Drawing Plan for Unit LocationInspect Unit Plan for Sequence of Unit InstallationProvide Unit Support Roof Curb Details Field Fabricate Ductwork For Units with Accessory Electric HeatersRig and Place Unit Convert to Horizontal and Connect Ductwork when required Install Outside Air HoodEconomizer Hood Removal and Setup Factory Option Positioning on CurbDamper Assembly Install External Condensate Trap and Line Economizer Hood and Two-Position HoodField Power Supply Make Electrical ConnectionsMounting Position for Field Disconnects Over 100A Units Without Factory-Installed Disconnect Units with Factory-Installed DisconnectUnit Powered Convenience Outlet Wiring Field Control Wiring Factory-Option Thru-Base ConnectionsThermostat Units without Thru-Base ConnectionsHeat Anticipator Settings Unit without Thru-Base Connection KitHeater and Supplementary Fuses Single Point BoxesHeater Low-Voltage Control Connections Return Air Enthalpy Sensor Outdoor Air Enthalpy Control PNO 33CSENTHSWDifferential Enthalpy Control RTU-MP Control System RTU-MP System Control Wiring Diagram Supply Air Temperature SAT Sensor RTU-MP Controller Inputs and OutputsOutdoor Air Temperature OAT Sensor Space Temperature SPT SensorsField Connections EconoMi$er2RTU-MP T-56 Sensor Connections Indoor Air Quality CO2 sensorOutdoor Air Quality Sensor PNO 33ZCSENCO2 plus Connecting Discrete InputsWeatherproof enclosure Communication Wiring Protocols Local AccessRTU-MP Troubleshooting GeneralLEDs LEDs on the RTU-MP show the status of certain functionsSmoke Detectors SystemController SensorSupply Air Smoke Detector LocationsReturn Air with Economizer Completing Installation of Return Air Smoke Sensor Return Air Detector Shipping PositionUnit Wire/Fuse or Hacr Breaker Sizing Data NonePwrd C.O Adjust Factory-Installed Options EconoMi$er IV Occupancy SwitchInstall Accessories Pre-Start and Start-Up548J*14D 548J*14D Catalog No. II548J---07

548J*14D specifications

The Bryant 548J*14D is a highly efficient and versatile air conditioning unit designed to meet the varying demands of residential and light commercial applications. This model stands out due to its advanced engineering, energy-saving features, and reliable performance, making it an ideal choice for homeowners looking to enhance comfort without compromising on energy efficiency.

One of the main features of the Bryant 548J*14D is its excellent SEER (Seasonal Energy Efficiency Ratio) rating, which signifies its ability to provide cooling while consuming less energy. Optimized for efficiency, this unit employs a high-efficiency compressor that adjusts its output based on cooling demands, allowing it to use only the energy necessary to maintain a comfortable environment.

The unit’s all-aluminum evaporator coil ensures durability and resistance to corrosion, contributing to its longer lifespan and consistent performance. Additionally, the Bryant 548J*14D incorporates advanced refrigeration technologies for maximum heat transfer efficiency. This technology not only enhances cooling performance but also improves overall system reliability.

A key characteristic of the Bryant 548J*14D is its Whisper Series technology designed for quiet operation. The low-noise design minimizes sound levels, allowing for unobtrusive cooling in residential spaces while still ensuring effective airflow and cooling capacity. This makes it particularly favorable for installation in bedrooms and other noise-sensitive areas.

Another noteworthy aspect of the Bryant 548J*14D is its compatibility with the MyBryant smartphone app, which enables homeowners to monitor and control their HVAC systems remotely. This connectivity offers convenience and helps to optimize energy usage, as users can adjust settings based on their schedules and preferences.

Furthermore, the Bryant 548J*14D is designed with a robustness that allows it to withstand diverse weather conditions, ensuring reliable performance even in extreme climates. The unit’s compact design eases installation in various settings, whether it's on rooftops, near walls, or on concrete pads.

In summary, the Bryant 548J*14D is a cutting-edge air conditioning unit that combines energy efficiency, quiet operation, and advanced technologies. With its robust construction, smart features, and reliable performance, it stands as a valuable solution for anyone looking to enhance comfort and save on energy costs in their homes or light commercial environments.