Emerson Complete Guide for Installing and Troubleshooting the 1F82-261 Thermostat

Page 2

INSTALLATION

REMOVE OLD THERMOSTAT

1.Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.

2.Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermo- stat and the wall mounting plate as an assembly.

3.Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.

4.Disconnect the wires from old thermostat one at a time. DO

NOT LET WIRES FALL BACK INTO THE WALL.

5.Install new thermostat using the following procedures.

ATTENTION!

This product does not contain mercury. However, this product may replace a unit which contains mercury.

Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be dis- carded.

Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container. Refer to www.white-rodgers.com for loca- tion to send the product containing mercury.

ATTACH THERMOSTAT BASE TO WALL

1.Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit.

2.Connect wires beneath terminal screws on base using appropriate wiring schematic (see figs. 2 through 4).

3.Place base over hole in wall and mark mounting hole locations on wall using base as a template.

4.Move base out of the way. Drill mounting holes.

5.Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase.

6.Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

ELECTRIC/GAS JUMPER (Fan Option)

Read the following information before clipping the nonelectric heat jumper. If you are unsure of your application, contact a qualified service person.

If your emergency or auxiliary system will energize the blower, then jumper, W904, on the thermostat base must be cut (see fig. 1).

If your emergency or auxiliary heat system requires that the thermostat energize the fan circuit, do not cut jumper W904.

OPTIONAL BATTERIES

With two "AA" batteries installed, your thermostat will maintain time and continuously display the temperature during a loss of

Optional (2) "AA" batteries

Screw anchors

O/B

switch

Mounting hole

Reset switch

(below Fan switch)W904

Mounting

Electric/Gas hole jumper

Figure 1. Thermostat Base

AC power. Installed batteries will also allow programming prior to installation. For best results, use new premium brand batteries such as Duracell® or Energizer® .

ENERGY MANAGEMENT RECOVERY

(EMR)

When the EMR feature is activated the thermostat's microcom- puter calculates the time it will take to change the room temperature to the next heat or cool program setting. Then the thermostat will start the system before the next programmed period so that the desired temperature is reached at or near the beginning of the period (the thermostat calculates 15 minutes for every 1°F temperature change). This minimizes the use of auxiliary stages during the transition period to reduce energy costs.

For example: The thermostat is programmed to provide an overnight heating temperature of 66°F, and during the next program period, beginning at 6:00 AM, the programmed tem- perature is 70°F. With EMR activated, the thermostat will automatically start the heating system at 5:00 AM, so that the programmed temperature of 70°F is reached by about 6:00 AM.

If the overnight room temperature drops only to 68F°, the thermostat will start the system at 5:30 to reach the programmed temperature of 70°F at 6:00.

The thermostat is shipped with the EMR feature active, which means that the thermostat will start the heating system before the beginning of the next program period. This feature provides better efficiency by allowing gradual temperature changes using only the first stage of heat.

To deactivate the EMR function, see the Configuration menu on Page 5). The thermostat will then wait until the programmed time to start the system for a temperature change.

O/B TERMINAL SWITCH SELECTION

The O/B switch on this thermostat is factory set to the “O” position. This will accommodate the majority of heat pump applications, which require the changeover relay to be ener- gized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a “B” termi- nal, to energize the changeover relay in HEAT, the O/B switch must be moved to the “B” position.

2

Image 2
Contents Description PrecautionsSpecifications Installation Thermostat SystemThermostat Base OperationCheck Thermostat Operation Display Configuration MenuConfiguration Menu Planning Your Program Manual OperationProgramming Your Thermostat Enter Cooling Program Entering Your ProgramSet Current Time and Day Enter Heating ProgramReset Operation TroubleshootingSymptom Possible Cause Corrective Action
Related manuals
Manual 2 pages 11.99 Kb

1F82-261 specifications

The Emerson 1F82-261 and 1F89-211 are advanced programmable thermostats designed to enhance home comfort, energy efficiency, and convenience. These devices represent the latest in heating and cooling management technology, aiming to provide homeowners with intuitive control over their indoor climate.

One of the primary features of the Emerson 1F82-261 is its user-friendly interface. The large backlit display is easy to read, even in low light conditions. Users can quickly adjust settings, view the current temperature, and access programming options without hassle. Both models come equipped with a touch screen feature, allowing for simple navigation through menus and settings compared to older dial models.

The 1F82-261 model supports up to 2 heating and 1 cooling stages, making it suitable for multi-stage HVAC systems. It is ideal for those looking to optimize home heating or cooling while ensuring comfort. On the other hand, the 1F89-211 is designed for even greater versatility, offering compatibility with up to 2 stages of heating and 2 stages of cooling. This makes it an excellent choice for larger or more complex heating and cooling systems.

A highlight of both thermostats is their programmability. Users can set schedules for different days of the week through a simple programming interface. This feature allows homeowners to reduce energy consumption by adjusting the temperature based on occupancy patterns, ensuring that energy is not wasted while the house is empty.

Another significant technology incorporated into these models is the Smart Response feature. This intelligent technology enables the thermostat to learn the household's heating and cooling patterns, making adjustments ahead of time to reach the desired temperature right when it is needed. This not only enhances comfort but also contributes to energy savings.

Further emphasizing energy efficiency, the Emerson thermostats include an auto-changeover feature for seamless transition between heating and cooling modes, depending on the current temperature. This technology ensures that your home maintains a consistent, comfortable climate throughout varying conditions.

Both models also support Wi-Fi connectivity, allowing for remote access and control via smartphone apps. This feature provides the convenience of monitoring and adjusting home temperatures from anywhere, enabling homeowners to arrive at a perfectly comfortable home after a long day.

In summary, the Emerson 1F82-261 and 1F89-211 combine modern design with intelligent features, making them ideal choices for anyone looking to enhance their home’s comfort and energy efficiency. With easy-to-use interfaces, advanced programmability, and smart technologies, these thermostats provide reliable solutions for efficient climate control.