Emerson 1F82-261 specifications Configuration Menu, Display

Page 5

The Display

9Indicates day of the week.

10Indicates a malfunction with the system.

11Flame icon () is displayed when the SYSTEM switch is in

the HEAT position. Flame icon () is displayed flashing when 2nd-stage heat (Aux or Emergency) is energized. Snowflake icon () is displayed (non-flashing) when the SYSTEM switch is in the COOL position. Snowflake and Flame are displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling too quickly.

12EMER is displayed flashing when the system switch is in EMER position.

13Alternately displays current time and temperature.

14The word HOLD is displayed when the thermostat is in the HOLD mode. HOLD is displayed flashing when the thermo- stat is in a temporary HOLD Mode.

15Displays currently programmed set temperature (this is blank when SYSTEM switch is in the OFF position).

16Displays FLTR when the system has run for the pro- grammed filter time period as a reminder to change or clean your air filter.

CONFIGURATION MENU

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal require- ments.

Press RUN to make sure the thermostat is in the run program mode, then press PRGM and RUN at the same time to enter the configuration menu. The display will show the first item in the configuration menu.

The configuration menu chart summarizes the configuration options. An explanation of each option follows.

Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation.

1)Select Temporary Hold Time - The thermostat can hold any temperature you set it to for the amount of time you select on this option. Your choices are 0:00 to 8:00 hours in 15 minute increments. 0:00 disables the function Example: Using the Temporary Hold Function

1.You have selected 3:00 hours for the Temporary Hold time period.

2.With the thermostat set to Heat or Cool, press HOLD for five seconds (time will show 3:00 hours as a setting reminder).

3.HOLD on the display will blink. Release the HOLD button after the temporary hold time is displayed.

4.Use or to set the temperature to your prefer- ence. The thermostat will maintain this temperature setting for 3 hours with HOLD blinking to remind you it is in Temporary Hold. After 3 hours the thermostat will go back to the program temperature and HOLD will no longer blink or display.

2)Select FA or SL (Fast or Slow) Heat Pump stage Cycle Rate - The FA setting is used to produce shorter heating cycles. The SL setting produces a longer heating/cooling cycle. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under .75°F and the SL setting cycles at approximately 1.2°F.

3)Select FA or SL (Fast or Slow) Auxiliary or Emergency Cycle Rate - The FA setting is frequently used for gas, oil or electric heat. The SL setting produces a longer heating cycle. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under .6°F and the SL setting cycles at approximately 1.°F.

Configuration Menu

Step

Press Button(s)

Displayed (Factory Default)

Press

or

to select:

COMMENTS

 

 

 

 

 

 

 

 

 

1

PRGM

HOLD

 

0 to 8 hrs (in

 

Select temporary Hold time

 

and RUN

(0:00)

15 minute increments)

 

 

 

 

 

 

 

 

 

 

2

HOLD*

 

 

 

 

FA

 

Select FA or SL (Fast or Slow) pump cycle rate

 

(SL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

HOLD*

EMER

 

SL

 

Select FA or SL (Fast or Slow) Auxiliary and

 

 

 

(FA)

 

 

 

Emergency Aux heating cycle rate

 

 

 

 

 

 

 

 

 

4

HOLD*

 

d-L

 

OFF

 

Select display backlight OFF or ON

 

 

 

(on)

 

 

 

 

 

 

 

 

 

 

 

 

 

5

HOLD*

 

E

 

OFF

 

Select Energy Management Recovery OFF or ON

 

 

 

(on)

 

 

 

 

 

 

 

 

 

 

 

6

HOLD*

 

Filter

0 to 1950 hours

Select filter replacement run time

 

 

(000)

(in 50 hour increments)

 

 

 

 

 

 

 

 

 

 

7

HOLD*

 

LOC

 

on

 

Select Compressor lockout OFF or ON

 

 

(OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

8

HOLD*

 

0 HI

 

4 LO to

 

Select temperature display adjustment higher or lower

 

 

(0)

 

4 HI

 

 

9

HOLD*

 

(F)

 

C

 

Select temperature display to F or C

 

 

 

 

 

 

 

 

 

10

HOLD*

 

FA

 

OFF

 

Select fast second stage ON or OFF

 

 

 

(on)

 

 

 

 

 

 

 

 

 

 

 

 

 

11

RUN

 

 

 

 

 

 

Returns to normal operation

 

 

 

 

 

 

 

 

 

*Press HOLD to advance to next item or TIME to move backwards to previous item

5

Image 5
Contents Description PrecautionsSpecifications Installation System ThermostatThermostat Base OperationCheck Thermostat Operation Display Configuration MenuConfiguration Menu Planning Your Program Manual OperationProgramming Your Thermostat Set Current Time and Day Entering Your ProgramEnter Cooling Program Enter Heating ProgramReset Operation TroubleshootingSymptom Possible Cause Corrective Action
Related manuals
Manual 2 pages 11.99 Kb

1F82-261 specifications

The Emerson 1F82-261 and 1F89-211 are advanced programmable thermostats designed to enhance home comfort, energy efficiency, and convenience. These devices represent the latest in heating and cooling management technology, aiming to provide homeowners with intuitive control over their indoor climate.

One of the primary features of the Emerson 1F82-261 is its user-friendly interface. The large backlit display is easy to read, even in low light conditions. Users can quickly adjust settings, view the current temperature, and access programming options without hassle. Both models come equipped with a touch screen feature, allowing for simple navigation through menus and settings compared to older dial models.

The 1F82-261 model supports up to 2 heating and 1 cooling stages, making it suitable for multi-stage HVAC systems. It is ideal for those looking to optimize home heating or cooling while ensuring comfort. On the other hand, the 1F89-211 is designed for even greater versatility, offering compatibility with up to 2 stages of heating and 2 stages of cooling. This makes it an excellent choice for larger or more complex heating and cooling systems.

A highlight of both thermostats is their programmability. Users can set schedules for different days of the week through a simple programming interface. This feature allows homeowners to reduce energy consumption by adjusting the temperature based on occupancy patterns, ensuring that energy is not wasted while the house is empty.

Another significant technology incorporated into these models is the Smart Response feature. This intelligent technology enables the thermostat to learn the household's heating and cooling patterns, making adjustments ahead of time to reach the desired temperature right when it is needed. This not only enhances comfort but also contributes to energy savings.

Further emphasizing energy efficiency, the Emerson thermostats include an auto-changeover feature for seamless transition between heating and cooling modes, depending on the current temperature. This technology ensures that your home maintains a consistent, comfortable climate throughout varying conditions.

Both models also support Wi-Fi connectivity, allowing for remote access and control via smartphone apps. This feature provides the convenience of monitoring and adjusting home temperatures from anywhere, enabling homeowners to arrive at a perfectly comfortable home after a long day.

In summary, the Emerson 1F82-261 and 1F89-211 combine modern design with intelligent features, making them ideal choices for anyone looking to enhance their home’s comfort and energy efficiency. With easy-to-use interfaces, advanced programmability, and smart technologies, these thermostats provide reliable solutions for efficient climate control.