Emerson 1F82-261 specifications Check Thermostat Operation, Thermostat Base

Page 4

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate properly, contact a qualified service person.

Turn on power to the system.

Fan Operation

If your system does not have a G terminal connection, skip to Heating System.

1.Move fan switch to ON position. The blower should begin to operate.

2.Move fan switch to AUTO position. The blower should stop immediately.

Heating System

1.Move SYSTEM switch to HEAT position. If the auxiliary heating system has a standing pilot, be sure to light it.

2.Press to adjust thermostat setting to 1° above room temperature. The Heat Pump system should begin to oper-

ate. However, if the Flame icon () and Snowflake icon () are flashing, the compressor lockout feature is operating (see Configuration menu, item 7).

3.Adjust temperature setting to 4° above room temperature. The auxiliary heat system should begin to operate and the Flame icon will be flashing.

4.Press to adjust temperature setting below room tem- perature. The heating system should stop operating.

Emergency System

EMER bypasses the Heat Pump to use the heat source wired to terminal E on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only.

1.Move SYSTEM switch to EMER position, EMER will flash on the display.

2.Press to adjust the thermostat above room tempera- ture. The Aux heating system will begin to operate. The Flame icon ()will display flashing to indicate that the Aux system is operating.

3.Press to adjust the thermostat below room tempera- ture. The Aux heating system should stop operating.

Cooling System

! CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.

1.Move SYSTEM switch to COOL position.

2.Press to adjust thermostat setting below room tempera- ture. The blower should come on immediately on high speed, followed by cold air circulation

3.Press to adjust temperature setting above room tem- perature. The cooling system should stop operating.

! CAUTION

Do not allow the compressor to run unless the com- pressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.

OPERATION

Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat con- sists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base. To replace the cover, line up the cover with the base and press until the cover snaps onto the base.

THE THERMOSTAT BASE

Other than and , the following buttons and switches are located on the bottom of the thermostat cover (see fig. 5).

The Thermostat Buttons and Switches

1Raises temperature setting.

2Lowers temperature setting.

3TIME button.

4 PRGM (program) button.

5 RUN (program) button.

6 HOLD temperature button.

7 FAN switch (ON, AUTO).

8 SYSTEM switch (COOL, OFF, HEAT, EMER).

4

 

 

 

 

 

1

 

 

 

 

 

2

 

 

 

FAN

OFF HEAT

TIME

PRGM

RUN

HOLD

 

 

 

 

 

 

ON

AUTO

COOL EMER

 

 

 

Fltr

 

 

3

4

5

6

7

8

9

9 10

MO TU WE TH FR

 

 

 

SA SU

MALF

 

 

AM

 

 

 

 

 

 

 

 

 

PM

 

FLTR

 

 

 

HOLD EMER

 

16

13

15

11

14

13 12

11

Figure 5. Thermostat display, buttons, and switches

Image 4
Contents Specifications PrecautionsDescription Installation Thermostat SystemCheck Thermostat Operation OperationThermostat Base Configuration Menu Configuration MenuDisplay Programming Your Thermostat Manual OperationPlanning Your Program Entering Your Program Set Current Time and DayEnter Cooling Program Enter Heating ProgramSymptom Possible Cause Corrective Action TroubleshootingReset Operation
Related manuals
Manual 2 pages 11.99 Kb

1F82-261 specifications

The Emerson 1F82-261 and 1F89-211 are advanced programmable thermostats designed to enhance home comfort, energy efficiency, and convenience. These devices represent the latest in heating and cooling management technology, aiming to provide homeowners with intuitive control over their indoor climate.

One of the primary features of the Emerson 1F82-261 is its user-friendly interface. The large backlit display is easy to read, even in low light conditions. Users can quickly adjust settings, view the current temperature, and access programming options without hassle. Both models come equipped with a touch screen feature, allowing for simple navigation through menus and settings compared to older dial models.

The 1F82-261 model supports up to 2 heating and 1 cooling stages, making it suitable for multi-stage HVAC systems. It is ideal for those looking to optimize home heating or cooling while ensuring comfort. On the other hand, the 1F89-211 is designed for even greater versatility, offering compatibility with up to 2 stages of heating and 2 stages of cooling. This makes it an excellent choice for larger or more complex heating and cooling systems.

A highlight of both thermostats is their programmability. Users can set schedules for different days of the week through a simple programming interface. This feature allows homeowners to reduce energy consumption by adjusting the temperature based on occupancy patterns, ensuring that energy is not wasted while the house is empty.

Another significant technology incorporated into these models is the Smart Response feature. This intelligent technology enables the thermostat to learn the household's heating and cooling patterns, making adjustments ahead of time to reach the desired temperature right when it is needed. This not only enhances comfort but also contributes to energy savings.

Further emphasizing energy efficiency, the Emerson thermostats include an auto-changeover feature for seamless transition between heating and cooling modes, depending on the current temperature. This technology ensures that your home maintains a consistent, comfortable climate throughout varying conditions.

Both models also support Wi-Fi connectivity, allowing for remote access and control via smartphone apps. This feature provides the convenience of monitoring and adjusting home temperatures from anywhere, enabling homeowners to arrive at a perfectly comfortable home after a long day.

In summary, the Emerson 1F82-261 and 1F89-211 combine modern design with intelligent features, making them ideal choices for anyone looking to enhance their home’s comfort and energy efficiency. With easy-to-use interfaces, advanced programmability, and smart technologies, these thermostats provide reliable solutions for efficient climate control.