Envision Peripherals IM1603 installation manual Hydronic Models, =/2C

Page 11

ENVISION SERIES AIR HANDLER INSTALLATION MANUAL

Hydronic Models

The water heater and hydronic air handler must be lo- cated indoors and not subject to freezing temperatures. The water heater must be installed in accordance to local codes and its own installation instructions. The piping between the water heater and air handler should be kept to a minimum. Piping should be sized to allow for water velocities of 2’-4’ per second. At average water velocities, air bubbles should be carried along the piping to an air separator where they can be discharged from the system. Water velocities greater than 4’ per second could cause flow noise and should be avoided. If water lines pass through an unconditioned space they should be protected to prevent them from freezing. Valves should be installed to allow system isolation. All closed loop hydronic systems must be equipped with an expansion tank to allow room for the heated liquid to expand. A system is considered closed when a check valve or backflow prevention valve is installed in the cold water pipe upstream of the water heater.

Once piping is complete all air must be purged from the wa- ter lines. There is a dole valve at the top of the hydronic coil header that can be opened to purge air from the coil. There is also a plug at the bottom of the hydronic coil header for draining the coil.

Dole valve for air purging

Plug for coil drainage.

Typical Installation. See the Hydronic Application Guide for other applications

!>A7

@3:734D/:D3

0OQY4Z]e>`SdS\bS` >`Saac`S@SZWSTDOZdS

2WSZSQb`WQ

C\W]\a

>`Saac`S

5OcUS

/W`

DS\b

:=/2>C;>

/W`

AS^O`Ob]`

3f^O\aW]\

BO\Y

>B>]`ba

53=

AB=@/53

B/<9

 Þ

2WSZSQb`WQ4>B C\W]\a

0OZZDOZdS

<=B3(/!>A7^`Saac`S`SZWSTdOZdS >O`b<](A@D!aV]cZRPScaSRW\ VgR`]\WQO^^ZWQObW]\a

EObS`4c`\OQS

6G2@=<71/7@6/<2:3@

B= 4@=;

2A6 2A6

A]c`QS7<

>B>]`ba

>B>]`ba

A]c`QS=CB

EObS`4c`\OQS

6G2@=<71C<7B

10

Image 11
Contents Envision Series Air Handler Installation Manual WaterFurnace Table of Contents Initial Inspection NomenclatureSafety Considerations General Installation InformationDuct System Moving and StorageUnit Location Condensate Drain Air Handler ConfigurationBottomflow Application System Evacuation Air Handler InstallationLeak Testing Connection to the CoilRefrigerant Line Sizing TXV Superheat AdjustmentsRefrigeration Charging the SystemDecrease Superheat Open Valve Increase Superheat Close Valve =/2C Hydronic ModelsWater Presure Drop Hydronic Coil Coil Capacity vs. Entering Water TemperatureElectrical Data 208v 240v Low Voltage Point to Point Wiring208-230/60/1 Wiring Schematic`6O\RZS`e YE3ZSQb`WQ6SOb ECM Blower Control Cooling/Heating settingsDehumidification Mode settings Blower Performance Dip Switch SettingsAir Coil Maintenance FiltersUnit Start Up Blower MotorsTop Flow/Horizontal Unit Configuration Dimensional Data=D73E @=BD73E @756BA723D73E =BB=D73E Bottom Flow Unit ConfigurationObtaining Parts Replacement ProceduresWarranty Material Return Product

IM1603 specifications

Envision Peripherals IM1603 is a state-of-the-art display solution designed to cater to the diverse needs of various sectors, including retail, corporate, and education. This innovative device combines advanced technology with user-friendly features, making it a robust choice for organizations looking to enhance their visual communication strategies.

One of the standout features of the IM1603 is its high-definition display, which boasts impressive resolution and vivid color accuracy. With its 16:9 aspect ratio, the screen offers a cinematic viewing experience, making it perfect for sharing presentations, videos, and graphics in high clarity. The touchscreen functionality adds to its versatility, allowing users to interact directly with the display. This is particularly beneficial in educational environments where interactive learning tools are essential.

The IM1603 is built with durability in mind. It features a rugged design that can withstand the rigors of daily use, ensuring that it remains functional in busy settings. This reliability is complemented by the enhanced brightness levels, which ensure that the content is easily viewable even in well-lit environments. The anti-glare surface minimizes reflections, making it user-friendly for both presenters and viewers.

Connectivity is another strong point of the Envision Peripherals IM1603. It comes equipped with multiple input options, including HDMI, VGA, and USB ports, enabling seamless integration with various devices such as laptops, media players, and cameras. This flexibility ensures that users can easily switch between different sources without the need for complicated setups.

Moreover, the IM1603 incorporates advanced LED technology, which not only improves energy efficiency but also extends the lifespan of the display. This means that organizations can enjoy long-term use without the frequent need for replacements, making it a cost-effective solution.

In terms of installation, the IM1603 offers several mounting options, including wall mounts and stands, providing flexibility to fit different setups. This adaptability makes it suitable for a wide range of applications, from digital signage in retail spaces to interactive presentations in corporate environments.

In conclusion, the Envision Peripherals IM1603 stands out as a premier display solution that combines exceptional visual quality, durability, and connectivity. Its advanced features cater to the needs of various industries, making it an ideal choice for those seeking to elevate their display capabilities. With the IM1603, organizations can engage their audiences more effectively and create impactful visual experiences.