Switch action
CAUTION:
Before plugging in the tool, always check to see that the switch trigger actuates properly and returns to the "OFF" position when released.
To start the tool, simply pull the trigger.
Release the trigger to stop.
Speedchange
The revolutions and blows per minute can be adjusted just by turning the adjusting dial. The dial is marked 1 (lowest speed) to 6
(full speed). Refer to the table below for
the relationship between the number set- | ||
tings on the adjusting dial and the revolu- | ||
tions/blows per minute. | Adjusting dial - | |
|
| |
Number on | Revolutions | Blows |
adjusting dial | per minute | per minute |
6 | 240 | 2,550 |
5 | 230 | 2,450 |
4 | 200 | 2,100 |
3 | 160 | 1,700 |
2 | 130 | 1,300 |
1 | 120 | 1.250 |
Depth gauge
The depth gauge is convenient for drilling
holes of uniform depth. Loosen the clampClamp screw 7 screw and adjust the depth gauge to the
desired depth. After adjusting, tighten the clamp screw firmly.
NOTE:
The depth gauge cannot be used at the position where the depth gauge strikes against the gear housing/motor housing.
8